Evaluation of a New Device for Simplifying and Standardizing Stool Sample Preparation for Viral Molecular Testing
Linda Feghoul1, Maud Salmona1, Janine Cherot1
1Université Paris Diderot, Sorbonne Paris Cité, Inserm U941, Microbiology Laboratory, Hôpital Saint-Louis, APHP, Paris, France.
Abstract:
Sensitive molecular assays have greatly improved the diagnosis of viral gastroenteritis. However, the proper preparation of stool samples for clinical testing remains an issue. bioMérieux has developed a stool preprocessing device (SPD) that includes a spoon for calibrated sampling and a vial containing buffer, glass beads, and two filters. The resulting stool filtrate is used for nucleic acid extraction. The purpose of this study was to evaluate the performance of the SPD for the quantification of human adenovirus (HAdV) DNA in stool samples collected from hematopoietic stem cell transplant (HSCT) recipients. HAdV DNA was quantified with the Adenovirus R-gene kit. The suitability of the device to reproducibly quantify HAdV DNA in stools using different extraction platforms (easyMAG and QIAsymphony) was determined using archived HAdV-positive stool samples. Coefficients of variation of HAdV DNA quantifications ranged from 1.79% to 1.83%, and no difference in quantification was observed between the two extraction systems. The HAdV DNA limit of quantification using the SPD was 3.75 log10copies/g of stool. HAdV DNA quantification using the SPD was then compared to that of the routine preprocessing technique on 75 fresh stool samples collected prospectively from pediatric HSCT recipients at risk for HAdV infections. Thirty-eight samples were HAdV DNA positive with both the SPD and routine preprocessing methods. HAdV DNA loads were on average 1.14-log10copies/g of stool higher with the SPD (P< 0.0001) than with routine methods. This new device enabled a standardized preparation of stool samples in <5 min and a reproducible and sensitive quantification of HAdV DNA. The use of the SPD for the detection of other gastrointestinal infections warrants further evaluation.
More Related Videos
07:24A Hybrid DNA Extraction Method for the Qualitative and Quantitative Assessment of Bacterial Communities from Poultry Production Samples
Published on: December 10, 2014
06:59Rapid, Safe, and Simple Manual Bedside Nucleic Acid Extraction for the Detection of Virus in Whole Blood Samples
Published on: June 30, 2018