Related Experiment Video
Updated: Mar 27, 2026

Microbial DNA Analysis in the Field Using a Biological Extraction Field Kit and a Field qPCR Unit
Published on: January 2, 2026
Simulated radioactive decontamination of biological samples using a portable DNA extraction instrument for rapid DNA
Chantal J Frégeau1, Claude Dalpé1
1Royal Canadian Mounted Police, National Forensic Laboratory Services-Ottawa, 1200 Vanier Parkway, Ottawa, ON, Canada K1A 0R2.
Abstract:
A portable DNA extraction instrument was evaluated for its ability to decontaminate blood and saliva samples deposited on different surfaces (metal, plastic and glass) contaminated with stable isotopes of cobalt (Co), cesium (Cs), and strontium (Sr) as equivalents to their radiogenic (60)Co, (137)Cs, and (90)Sr isotopes, respectively, that could be released during a nuclear weapon accident or a radiological dispersal device (RDD) detonation. Despite the very high contamination levels tested in this study, successful removal of greater than 99.996% of the Co, Cs, Sr contaminants was achieved based on inductively coupled plasma-mass spectrometry (ICP-MS) and neutron activation analyses carried out on all liquids (including DNA eluates) and solid waste produced during automated DNA extraction. The remaining amounts of Co, Cs and Sr in the DNA eluates, when converted to dose rates (corresponding to (60)Co, (137)Cs and (90)Sr), were determined to be below the recommended dose limits for the general public in most of the scenarios tested. The presence of Co, Cs and Sr contaminants in the cell lysates had no adverse impact on the binding of DNA onto the magnetic DNA IQ™ beads. DNA yields were similar to uncontaminated controls. The remaining Co, Cs and Sr in the DNA eluates did not interfere with real-time PCR DNA quantification. In addition, the quality of the AmpFlSTR(®) Identifiler(®) profiles derived in 26min using an accelerated protocol was very good and comparable to controls. This study emphasizes the use of an accelerated process involving a portable DNA extraction instrument to significantly reduce radioactive dose rates to allow contaminated samples to be processed safely in a forensic mobile laboratory to expedite the identification of individuals potentially involved in the dispersal of nuclear or other radioactive materials.
More Related Videos
10:16Employing Digital Droplet PCR to Detect BRAF V600E Mutations in Formalin-fixed Paraffin-embedded Reference Standard Cell Lines
Published on: October 8, 2015
07:13Swabbing the Urban Environment - A Pipeline for Sampling and Detection of SARS-CoV-2 From Environmental Reservoirs
Published on: April 9, 2021