Related Experiment Video
Updated: Mar 27, 2026

Echocardiographic Evaluation of Atrial Communications before Transcatheter Closure
Published on: February 8, 2022
3D Assessment of Features Associated With Transvalvular Aortic Regurgitation After TAVR: A Real-Time 3D TEE Study
Kentaro Shibayama1, Hirotsugu Mihara2, Hasan Jilaihawi2
1Cedars-Sinai Heart Institute, Los Angeles, California; Heart Center, Tokyo Bay Urayasu/Ichikawa Medical Center, Urayasu, Japan.
Objectives:
This study of 3-dimensional (3D) transesophageal echocardiography (TEE) aimed to demonstrate features associated with transvalvular aortic regurgitation (AR) after transcatheter aortic valve replacement (TAVR) and to confirm the fact that a gap between the native aortic annulus and prosthesis is associated with paravalvular AR.
Background:
The mechanism of AR after TAVR, particularly that of transvalvular AR, has not been evaluated adequately.
Methods:
All patients with severe aortic stenosis who underwent TAVR with the Sapien device (Edwards Lifesciences, Irvine, California) had 3D TEE of the pre-procedural native aortic annulus and the post-procedural prosthetic valve.
Results:
In the 201 patients studied, the total AR was mild in 67 patients (33%), moderate in 21 patients (10%), and severe in no patients. There were 20 patients with transvalvular AR and 82 patients with paravalvular AR. Fourteen patients had both transvalvular and paravalvular AR. Patients with transvalvular AR had larger prosthetic expansion (p <0.05), a more elliptical prosthetic shape at the prosthetic commissure level (p <0.01) and more anti-anatomical position (p <0.001), which was defined as malposition of the prosthetic commissures in relation to the native commissures, than the patients without transvalvular AR. Age (odds ratio [OR]: 1.05; 95% confidence interval [CI]: 1.01 to 1.09; p < 0.05) and effective area oversizing (OR: 0.97; 95% CI: 0.93 to 0.99, p <0.05) were associated with mild or greater paravalvular AR.
Conclusions:
3D TEE successfully demonstrated the features associated with transvalvular AR, such as large prosthetic expansion, elliptical prosthetic shape, and anti-anatomical position of prosthesis. Additionally, effective area oversizing was associated with paravalvular AR.
Related Concept Videos
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Aortic Regurgitation IV: Nursing Management
Aortic Regurgitation III: Medical Management
Aortic Regurgitation I: Introduction
Mitral Regurgitation III: Medical Management
Rheumatic Heart Disease II: Clinical Manifestations and Diagnostic Studies