Upper limbs total occlusion pressure assessment: Doppler ultrasound reproducibility and determination of predictive
André T Bezerra de Morais1, Mikhail Santos Cerqueira1, Rafael Moreira Sales1
1Department of Physiotherapy, Federal University of Pernambuco, Recife, Brazil.
Abstract:
Total occlusion pressure (TOP) is an important variable to ischaemic exercise training because the optimal pressure of flow restriction (OPR), applied during this exercise modality, is derived from it. Despite the common use of Doppler ultrasound (DU) to determine the TOP, the reproducibility of this assessment was not evaluated yet. Given this, the objective was to evaluate the reproducibility of DU for the measurement of TOP in upper limbs and determine the predictive variables. Thirteen male volunteers attended three times to the laboratory. On the 1st day, we assessed arm circumference (AC), systolic blood pressure (SBP) and diastolic (DBP), and brachial artery TOP. On 2nd and 3rd days, only TOP was assessed. We found a coefficient of variation of 5·6% and an intraclass correlation coefficient of 0·795 for the DU. In the analysis of TOP predictive variables, the Spearman coefficients (R) were 0·813 (SBP), 0·786 (DBP) and 0·388 (AC). Therefore, these results support that DU has good reproducibility for the TOP and that SBP and DBP should be considered to the determination of TOP in upper limbs.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Assessing Blood Pressure
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)