Related Experiment Video
Updated: Mar 27, 2026

Evaluating Regional Pulmonary Deposition using Patient-Specific 3D Printed Lung Models
Published on: November 11, 2020
Influence of secondary aspiration on human aspiration efficiency
K R Anderson1, T Renee Anthony1
1Department of Occupational and Environmental Health, University of Iowa, 105 River Street, Iowa City, IA 52242, USA.
Abstract:
Computational fluid dynamics (CFD) was used to evaluate the contribution of secondary aspiration to human aspiration efficiency estimates using a humanoid model with realistic facial features. This study applied coefficient of restitution (CoR) values for working-aged human facial skin to the facial regions on the humanoid CFD model. Aspiration efficiencies for particles ranging from 7 to 116 μm were estimated for bounce (allowing for secondary aspiration) and no-bounce (CoR=0) simulations. Fluid simulations used the standard k-epsilon turbulence model over a range of test conditions: three freestream velocities, two breathing modes (mouth and nose breathing, using constant inhalation), three breathing velocities, and five orientations relative to the oncoming wind. Laminar particle trajectory simulations were used to examine inhaled particle transport and estimate aspiration efficiencies. Aspiration efficiency for the realistic CoR simulations, for both mouth- and nose-breathing, decreased with increasing particle size, with aspiration around 50% for 116 μm particles. For the CoR=0 simulations, aspiration decreased more rapidly with increasing particle size and approached zero for 116 μm compared to realistic CoR models (differences ranged from 0% to 80% over the particle sizes and velocity conditions). Differences in aspiration efficiency were larger with increasing particle size (>52 μm) and increased with decreasing freestream velocity and decreasing breathing rate. Secondary aspiration was more important when the humanoid faced the wind, but these contributions to overall aspiration estimates decreased as the humanoid rotated through 90°. There were minimal differences in aspiration between uniform CoR values of 0.5, 0.8, 1.0 and realistic regionally-applied CoR values, indicating differences between mannequin surfaces and between mannequin and human skin will have negligible effect on aspiration for facing-the-wind orientation.
More Related Videos
08:30Intraperitoneal Glucose Tolerance Test, Measurement of Lung Function, and Fixation of the Lung to Study the Impact of Obesity and Impaired Metabolism on Pulmonary Outcomes
Published on: March 15, 2018
08:58Assessment of Respiratory Function in Conscious Mice by Double-chamber Plethysmography
Published on: July 10, 2018
Related Concept Videos
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs...
Mechanism of Breathing III: The Accessory Muscles
The respiratory system is a complex network that relies on primary respiratory muscles like the diaphragm, but also involves accessory muscles to enhance lung expansion and airflow during both inhalation and exhalation.
Enhancing Inhalation with Accessory Muscles:
Accessory muscles such as the sternocleidomastoid, scalene, intercostal, and abdominal muscles are crucial when additional respiratory effort is required, such as during deep...