Micro-CT evaluation of rheumatoid arthritis mouse model disease progression: Manual tracings versus semi-automated

A C Antill1, D H Ballard1, A M Hollister2

  • 1Department of Surgery, Louisiana State University Health Shreveport, 1501 Kings Highway, Shreveport, 71130 Louisiana, USA.

Abstract

Insights

Manual correction of micro-CT imaging regions of interest improves assessment of bone volume loss in rheumatoid arthritis (RA) mouse models, offering a more effective evaluation of joint changes.

Area of Science:

  • Biomedical Imaging
  • Osteoarthritis Research
  • Animal Models

Background:

  • Rheumatoid arthritis (RA) poses significant challenges in assessing joint damage.
  • Micro-computed tomography (micro-CT) is a valuable tool for in vivo imaging.
  • Accurate quantification of bone loss in RA models requires precise region of interest (ROI) identification.

Purpose of the Study:

  • To evaluate the utility of micro-CT imaging in a collagen-induced arthritis (CIA) mouse model.
  • To determine if manual correction of semi-automated ROIs enhances the assessment of bone volume and density loss.
  • To compare manual versus semi-automated ROI analysis in quantifying RA-induced skeletal changes.

Main Methods:

  • Collagen-induced arthritis (CIA) was induced in DBA/1J mice, with a control group.
  • Micro-CT scans were performed at multiple time points post-induction.
  • Semi-automated ROIs of the humerus and femur were manually refined to correct edge irregularities.
  • Bone volume and density were calculated and compared between methods.

Main Results:

  • Significant differences in bone volume data were observed between manually corrected and semi-automated ROIs across all time points and skeletal sites.
  • No significant differences in bone density (Hounsfield units) were found between the two ROI methods, with one exception.
  • Histological analysis provided complementary data on joint changes.

Conclusions:

  • Manual correction of semi-automated ROIs in micro-CT imaging significantly improves the accuracy of bone volume assessment in RA mouse models.
  • This refined approach allows for more effective quantification of bone volume, density, and joint surface alterations.
  • The findings support the integration of manual ROI refinement for robust skeletal change evaluation in RA research.