The importance of catheter stability evaluated by Visitag(TM) during pulmonary vein isolation
Ryudo Fujiwara1, Kimitake Imamura2, Yoichi Kijima2
1Department of Cardiology, Saiseikai Nakatsu Hospital, Shibata 2-10-39, Kita-ku, Osaka-shi, Osaka, 530-0012, Japan. snowreveries119@yahoo.co.jp.
Background:
The recurrence rates of atrial fibrillation (Af) after ablation are still high, and repeat procedures are required in these patients. The main reason for Af recurrence is the recovery of the conduction between the pulmonary veins and left atrium. The importance of catheter stability during the pulmonary vein isolation (PVI) is not well studied.
Purpose:
The purpose of this study was to evaluate the contact force (CF), stable ablation time, and power during conduction blocking lesion formation for PVI.
Methods:
Thirty-two consecutive drug-refractory Af patients who underwent an initial PVI using CARTO 3 and Visitag were included. The CF, ablation time, force time integral (FTI), and ablation power were recorded by Visitag. Residual conduction gap points requiring touch-up ablation after an encircling linear ablation (R point), spontaneous reconnection points (S point), and dormant conduction points (D point) were considered as non-conduction blocking lesion points. Each ablation parameter for the non-conduction blocking lesion points was compared with the other lesion points.
Results:
Twenty-one points in 16 patients were considered non-conduction blocking lesions. Ten were R, eight were S, and three were D points. The CF, ablation time, FTI, and power at the non-conduction blocking lesion points and other points were 12.0 g (7.0-21.5) and 12.0 g (9.0-16.0) (P = 0.9), 7.7 s (5.6-10.1) and 12.5 s (9.4-16.8) (P < 0.05), 103.0 g*s (62.0-174.5) and 149.0 g*s (104.0-213.0) (P < 0.05), and 30.0 W (22.5-30.0) and 30.0 W (30.0-30.0) (P = 0.06), respectively.
Conclusions:
Shorter ablation time recorded in Visitag lead to non-conduction blocking lesion.
More Related Videos
06:48Three-Dimensional Echocardiographic Method for the Visualization and Assessment of Specific Parameters of the Pulmonary Veins
Published on: October 28, 2020
06:59Catheter-based Endovascular Angioplasty for Fibrosing Mediastinitis-associated Pulmonary Vein Stenosis
Published on: August 26, 2025
Related Concept Videos
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization IV: Nursing Management
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization I: Pre-Procedure Overview
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies