Related Experiment Video
Updated: Mar 27, 2026

Image Acquisition Method for the Sonographic Assessment of the Inferior Vena Cava
Published on: January 13, 2023
Changes in Sonographically Measured Inferior Vena Caval Diameter in Response to Fluid Loading in Term Pregnancy
Celso A Hernandez1, Kathryn L Reed2, Elizabeth B Juneman2
1Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology (C.A.H., K.L.R., W.R.C.), and Division of Cardiovascular Medicine, Department of Medicine, (E.B.J.) University of Arizona College of Medicine, Tucson, Arizona USA. celsohernandezmd@gmail.com.
Objectives:
The purpose of this study was to determine whether the inferior vena caval (IVC) diameter is influenced by intravascular volume changes in pregnancy.
Methods:
A prospective observational study was done on 2 groups of normal term gravidas. In 24 patients, we measured the IVC diameter, blood pressure, and heart rate (HR) before and after a 1-L fluid infusion in preparation for regional anesthesia, after initiation of an epidural block, and within 24 hours postpartum. In a second group of 15 women, we measured the IVC diameter sequentially during a 1-L crystalloid infusion.
Results:
In the first group, the mean baseline IVC diameter ± SD at end-inspiration was 1.45 ± 0.32 cm, which was 19% smaller than at end-expiration (1.73 ± 0.31 cm; P= .003). This respiratory cycle variation remained significant at each measurement epoch. The mean caval diameter at end-inspiration increased by 23% after the fluid bolus (P = .012). Hydration was not, however, accompanied by any significant change in the HR, mean arterial pressure, or collapsibility index of the inferior vena cava. With epidural anesthesia, the mean arterial pressure decreased from 88 ± 9 to 80 ± 7 mm Hg (P= .018), but the HR and collapsibility index remained unchanged. Postpartum values were not significantly different from their baseline measurements, except for the mean arterial pressure, which was lower by about 6 mm Hg (P = .042). In the second group, the IVC diameter at end-inspiration increased by 31% after the 1-L infusion, and there was a positive correlation between the volume infused and the IVC diameter (r= 0.67; P< .0001).
Conclusions:
Measurable variations in the IVC diameter occur in response to volume changes in normal term pregnancy and postpartum.
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Overview of Systemic Veins
The coronary sinus, the heart's principal vein, resides in the coronary sulcus on the heart's posterior aspect. This broad venous channel receives nearly all venous blood from the myocardium, the heart muscle. It is fed by three primary veins: the great cardiac vein, the...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...

