Related Experiment Video
Updated: Mar 27, 2026

Author Spotlight: Integrating Alveolar-Capillary Reserve Measurements in Exercise Adaptation and Therapeutic Strategies
Published on: February 2, 2024
Test-Retest Reliability of Maximal and Submaximal Gas Exchange Variables in Patients With Coronary Artery Disease
Ellen Coeckelberghs1, Roselien Buys, Kaatje Goetschalckx
1Department of Rehabilitation Sciences (Ms Coeckelberghs, Dr Buys, Ms Pattyn, Dr Vanhees, and Dr Cornelissen), Faculty of Kinesiology and Rehabilitation Sciences, KU Leuven, Leuven, Belgium; and Department of Cardiovascular Sciences (Dr Goetschalckx), Faculty of Medicine, KU Leuven, Leuven, Belgium.
Purpose:
Gas exchange variables derived from cardiopulmonary exercise tests (CPETs) need to be reliable for evaluating interventions and clinical decision making. Whereas peak oxygen uptake ((Equation is included in full-text article.)O2) has shown to be a highly reliable parameter in patients with coronary artery disease (CAD), little is known about the reproducibility of these parameters in patients with CAD. Therefore, the purpose of this study was to confirm the reliability of peak (Equation is included in full-text article.)O2 and to investigate the reliability of submaximal CPET variables in patients with CAD.
Methods:
Eighty-five patients with CAD (57.6 ± 8.5 years; 79 males) performed 2 CPETs within 10 days before starting a rehabilitation program. Reliability of peak and submaximal exercise variables was assessed by using intraclass correlation coefficients (ICC), coefficients of variation, Pearson correlation coefficients, paired t tests, and Bland-Altman plots.
Results:
Maximal and submaximal exercise parameters showed adequate reliability. Overall, there was a good correlation across both testing occasions (r = 0.63-0.95; P < .05 for all). Peak (Equation is included in full-text article.)O2 (ICC, 0.95; 95% CI, 0.92-0.97) demonstrated excellent reliability. Of the submaximal exercise variables, oxygen uptake efficiency slope (OUES) was as reliable as peak (Equation is included in full-text article.)O2 (ICC, 0.97; 95% CI, 0.95-0.98). The ventilation/carbon dioxide production ((Equation is included in full-text article.)E/(Equation is included in full-text article.)CO2) slope showed very good test-retest reliability (ICC, 0.87; 95% CI, 0.80-0.91) and the (Equation is included in full-text article.)O2/work rate slope showed good reliability (ICC, 0.76; 95% CI, 0.64-0.85).
Conclusions:
Both peak (Equation is included in full-text article.)O2 and OUES show excellent test-retest reliability. Accordingly, in the case of no or unreliable peak (Equation is included in full-text article.)O2 data, we suggest using OUES to evaluate cardiorespiratory fitness in patients with CAD.
More Related Videos
07:26Conducting Maximal and Submaximal Endurance Exercise Testing to Measure Physiological and Biological Responses to Acute Exercise in Humans
Published on: October 17, 2018
04:20Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
Related Concept Videos
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Acute Coronary Syndrome III: Diagnostic Studies
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History