Chemical and physical processes in the retention of functional groups in plasma polymers studied by plasma phase mass

Joonas Ryssy1, Eloni Prioste-Amaral2, Daniela F N Assuncao3

  • 1School of Information Technology and Mathematical Sciences, University of South Australia, Mawson Lakes Campus, Mawson Lakes, SA 5095, Australia.

Related Concept Videos

Mass Spectrometry: Carboxylic Acid, Ester, and Amide Fragmentation01:01

Mass Spectrometry: Carboxylic Acid, Ester, and Amide Fragmentation

The fragmentation patterns observed for compounds such as carboxylic acids, esters, and amides in the mass spectra include ⍺-cleavage and McLafferty rearrangement. Fragmentation by ⍺-cleavage preferentially occurs at the carbon-carbon bond at the ⍺-position next to the carboxylic group to generate a neutral radical and a cation. Long chain compounds with hydrogen at their γ-carbon undergo McLafferty rearrangement to give a radical cation and a neutral alkene.
For example, the...
2.8K
Mass Spectrometry: Aromatic Compound Fragmentation01:23

Mass Spectrometry: Aromatic Compound Fragmentation

Upon ionization, aromatic compounds generate a molecular ion that is observed as a prominent peak in their mass spectra. For example, the molecular ion peak for benzene appears at a mass-to-charge ratio of 78, while toluene is observed at a mass-to-charge ratio of 92. The molecular ion benzene is highly stable and does not readily undergo further fragmentation due to the significant amount of energy required to disrupt the aromatic stability of the benzene ring. In contrast, the molecular ion...
2.7K
Gas Chromatography: Types of Columns and Stationary Phases01:17

Gas Chromatography: Types of Columns and Stationary Phases

Gas chromatography (GC) relies on stationary phases to separate and analyze components in a sample. There are two main types of stationary phases: liquid and solid. Liquid stationary phases are non-volatile, thermally stable, and chemically inert liquids coated onto the column. Solid stationary phases are particles of adsorbent material, such as silica gel or molecular sieves.
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
3.0K
Mass Spectrometry: Aldehyde and Ketone Fragmentation01:09

Mass Spectrometry: Aldehyde and Ketone Fragmentation

In mass spectrometry, the fragmentation of aliphatic aldehydes and ketones generally occurs through three key mechanisms: α-cleavage, inductive cleavage, and the McLafferty rearrangement.
5.2K
Mass Spectrometry: Molecular Fragmentation Overview01:20

Mass Spectrometry: Molecular Fragmentation Overview

The ionization of a molecule into a molecular ion inside the mass spectrometer causes instability in the molecule's structure due to the loss of an electron. This eventually leads to the fragmentation or breaking of some bonds in the molecule. The fragmentation occurs predominantly at specific bonds to yield relatively stable fragments.
One type of fragmentation pattern is the cleavage of a single bond in the molecular ion. The cleavage leads to a radical and a cation. The cleavage can occur at...
6.4K
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview01:19

Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview

In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then...
2.6K