Related Experiment Video
Updated: Mar 26, 2026

Workflow Based on the Combination of Isotopic Tracer Experiments to Investigate Microbial Metabolism of Multiple Nutrient Sources
Published on: January 22, 2018
Differentiation of ring-substituted bromoamphetamine analogs by gas chromatography-tandem mass spectrometry
Hiroyuki Inoue1, Shoko Negishi2, Yukiko Nakazono2
1National Research Institute of Police Science, 6-3-1 Kashiwanoha, Kashiwa, 277-0882 Japan.
Abstract:
There has been a rapid increase over the last decade in the appearance of new non-controlled psychoactive substances. Minor changes in the chemical structures of these compounds, such as the extension of an alkyl residue or replacement of a single substituent, are regularly made to avoid regulatory control, leading to the manufacture of many new potentially dangerous drugs. Bromoamphetamine analogs (bromoamphetamine [Br-AP] and bromomethamphetamine (Br-MA]) are ring-substituted amphetamines that can behave as stimulants, as well as exhibiting inhibitory activity towards monoamine oxidases in the same way as amphetamines. Gas chromatography-tandem mass spectrometry (GC-MS-MS) was used in this study to differentiate ring-substituted bromoamphetamine analogs. Free bases, trifluoroacetyl derivatives, and trimethylsilyl (TMS) derivatives of six analytes were successfully separated using DB-1ms and DB-5ms columns. Electron ionization MS-MS analysis of the TMS derivatives allowed for the differentiation of three regioisomers. TMS derivatives of 2-positional isomers provided significant product ions. The spectral patterns of 3- and 4-positional isomers were different. Chemical ionization MS-MS analysis of free bases for [M+H-HBr]+ ions at m/z 134 and 148 allowed for differentiation of the regioisomers. The spectra of 2-positional isomers contained characteristic product ions formed by dehydrogenation at m/z 132 and m/z 146 for 2Br-AP and 2Br-MA, respectively. The spectra of 3-positional isomers contained α-cleaved iminium cations as the base peaks. The spectra of 4-positional isomers showed a tropylium cation at m/z 91 as the base peak. These results demonstrate that GC-MS-MS can be used for the differentiation of regioisomeric Br-AP analogs in forensic practice.
More Related Videos
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Alkyl Halide Fragmentation
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
NMR Spectroscopy of Benzene Derivatives
Mass Spectrometry: Aromatic Compound Fragmentation
High-Resolution Mass Spectrometry (HRMS)

