Fragment-Based Screening for Enzyme Inhibitors Using Calorimetry
Michael I Recht1, Vicki Nienaber2, Francisco E Torres1
1Palo Alto Research Center, Palo Alto, California, USA.
Methods in Enzymology
|January 23, 2016
Summary
Isothermal titration calorimetry (ITC) offers sensitive, label-free analysis of binding and enzyme reactions. Nanocalorimetry enhances conventional ITC for efficient screening of compound libraries, overcoming limitations in reagent use and time.
Area of Science:
- Biophysical Chemistry
- Enzyme Kinetics
- Drug Discovery
Background:
- Isothermal titration calorimetry (ITC) is a sensitive method for studying binding thermodynamics and label-free enzyme kinetics.
- Conventional microcalorimetry is valuable for hit validation but limited in primary screening due to high reagent requirements and long assay times.
Purpose of the Study:
- To describe the application of nanocalorimetry and conventional microcalorimetry for screening compound libraries.
- To highlight nanocalorimetry's potential to overcome limitations of conventional ITC in fragment-based lead discovery.
Main Methods:
- Utilized isothermal titration calorimetry (ITC) with both conventional microcalorimeters and advanced nanocalorimeters.
- Applied label-free measurement techniques for enzymatic reactions.
- Screened compound libraries, including those typical in fragment-based lead discovery.
Main Results:
- Demonstrated the utility of nanocalorimetry for screening large compound libraries (500-1000 compounds).
- Showcased nanocalorimetry's ability to overcome the limitations of conventional ITC regarding reagent consumption and measurement duration.
- Validated the use of microcalorimetry for hit validation and characterization.
Conclusions:
- Nanocalorimetry offers a viable solution for primary screening of compound libraries in drug discovery.
- Both nanocalorimetry and conventional microcalorimetry are powerful tools for enzyme inhibitor screening.
- Label-free calorimetric methods provide essential thermodynamic and kinetic data for characterizing molecular interactions.