Measuring intestinal fluid transport in vitro: Gravimetric method versus non-absorbable marker
Jonathan M Whittamore1, Janet Genz2, Martin Grosell3
1Biosciences, College of Life and Environmental Sciences, University of Exeter, Exeter EX4 4QD, UK.
The gravimetric method is the most reliable for measuring net water flux (Jv) in vitro. Carbon-14-labeled polyethylene glycol ([(14)C]-PEG) 4000 is inconsistent and not recommended as a volume marker in gut sac preparations.
Area of Science:
- Physiology
- Gastroenterology
- Comparative Biology
Background:
- The gut sac preparation is a standard in vitro model for studying solute and water transport.
- Accurate assessment of net water flux (Jv) is crucial for these studies.
- Gravimetric measurement of mass change is the common method for determining volume, but may underestimate Jv due to tissue edema.
Purpose of the Study:
- To evaluate [(14)C]-PEG 4000 as a more representative in vitro volume marker for Jv compared to gravimetric methods.
- To compare the effectiveness of [(14)C]-PEG 4000 and gravimetric measurements across five teleost species.
Main Methods:
- Direct comparison of [(14)C]-PEG 4000 and gravimetric methods for Jv assessment in five teleost species.
- Investigated factors affecting PEG effectiveness, including adsorption and mucus sequestration.
Main Results:
- [(14)C]-PEG 4000 indicated significantly higher net fluid absorption in toadfish compared to gravimetric methods (approx. 4-fold).
- [(14)C]-PEG 4000 yielded inconsistent results across other species, often suggesting net secretion instead of absorption.
- PEG adsorption to tubes and sequestration in mucus were identified as issues impacting PEG effectiveness.
Conclusions:
- [(14)C]-PEG 4000 does not reliably overcome the limitations of gut sac preparations for accurate Jv measurement.
- The gravimetric method remains the most reliable approach for determining Jv in vitro.
- Caution is advised when using [(14)C]-PEG 4000 as a volume marker in gut sac studies.
More Related Videos
09:44Functional Assessment of Intestinal Motility and Gut Wall Inflammation in Rodents: Analyses in a Standardized Model of Intestinal Manipulation
Published on: September 11, 2012
10:22In Vitro and In Vivo Approaches to Determine Intestinal Epithelial Cell Permeability
Published on: October 19, 2018
Related Concept Videos
Methods for Studying Drug Absorption: In vitro
The diffusion cell method uses a two-compartment cell, including a donor compartment with the drug solution, which simulates the environment where the drug is applied, and a receptor compartment with a buffer solution, which simulates the environment...
Methods for Studying Drug Absorption: In situ
The Doluisio method involves perfusing a prepared segment of a rat's small intestine with a solution of radiolabeled drug and a non-absorbable marker. This helps to differentiate between absorbed and non-absorbed drug concentrations. The intestinal segment is connected at both ends using tubing and syringes,...
Microbial Growth Measurement: Indirect Methods