Characterization of the interface between cast-to Co-Cr implant cylinders and cast Co-Cr alloys
Ahmet Ozkomur1, Yurdanur Ucar2, Orhun Ekren3
1Postdoctoral Scholar, Department of Prosthodontics, Faculty of Dentistry, Pontifical Catholic University of Rio Grande do Sul, Porto Alegre, Brazil.
Statement Of Problem:
The affordable Co-Cr cast alloy should provide an ideal interface with prefabricated cast-to cylinders from the same alloy family. The alloy microstructures should be maintained up to the interface, and porosities and reaction regions should be absent, and sufficient bond strength between alloys should be provided.
Purpose:
The purpose of this in vitro study was to evaluate the metallurgical interfacial compatibility between Co-Cr dental casting alloys and a prefabricated Co-Cr dental implant cast-to-cylinder.
Material And Methods:
A Co-Cr alloy was cast to Co-Cr implant cylinders. Specimens were cross-sectioned longitudinally and divided into as-cast and heat-treated groups. The microstructures of specimens were evaluated by optical and scanning electron microscopy. The elemental composition of as-received prefabricated implant cylinders and diffusion characteristics of cast interfacial regions were determined by energy dispersive x-ray spectroscopy. Vickers hardness values were defined across the interface on cast specimens and for the as-received implant cylinders. ANOVA and Tukey honest significant differences tests were used for the statistical evaluation of hardness values.
Results:
No significant reaction regions or porosity were present in the interface. Microstructural aspect and interdiffusion indicated a metal-metal bond between the Co-Cr implant cylinder and cast alloy. Mean hardness values demonstrated a significant rise across the interface (373.5 ±12.8; 363.8 ±12.6, respectively) from the wrought cylinder (338.6 ±10.5; 329 ±9.7, respectively) to the cast alloy (399.8 ±7.4; 392.3 ±10.3, respectively) for the as-cast and heat-treated conditions, respectively.
Conclusions:
Co-Cr casting alloy cast on to prefabricated Co-Cr implant cylinders provided interfaces which appear to fulfill the requirements of the established criteria.
More Related Videos
Related Concept Videos
Mechanical Characteristics of Steel
The tension test is fundamental for determining tensile strength. In this test, a steel specimen is stretched using a gripping device until it breaks. The data collected during this test are used...
Metallic Solids
All metallic solids exhibit high thermal and electrical conductivity, metallic luster, and malleability....
Imperfections in Crystal Structure: Non-Stoichiometric Defects
Crystal Field Theory - Octahedral Complexes
To explain the observed behavior of transition metal complexes (such as colors), a model involving electrostatic interactions between the electrons from the ligands and the electrons in the unhybridized d orbitals of the central metal atom has been developed. This electrostatic model is crystal field theory (CFT). It helps to understand, interpret, and predict the colors, magnetic behavior, and some structures of coordination compounds of transition metals.
CFT focuses on...