Computed Tomography01:10

Computed Tomography

9.5K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
9.5K
Imaging Studies III: Computed Tomography01:27

Imaging Studies III: Computed Tomography

633
DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
633
Positron Emission Tomography01:29

Positron Emission Tomography

8.0K
Positron emission tomography (PET) is a medical imaging technique involving radiopharmaceuticals — substances that emit short-lived radiation. Although the first PET scanner was introduced in 1961, it took 15 more years before radiopharmaceuticals were combined with the technique and revolutionized its potential.
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
8.0K
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT01:25

Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT

791
Calcium-Scoring CT ScanA calcium-scoring CT scan, also known as coronary artery calcium (CAC) scan, detects calcium deposits in the coronary arteries. This test assesses the risk of coronary artery disease (CAD), which can lead to cardiovascular events such as angina, heart failure, and sudden cardiac arrest.A calcium-scoring CT scan is generally recommended for individuals at intermediate risk of CAD without symptoms. It includes:Men aged 40-75 and women aged 50-75: Especially those with a...
791
Imaging Studies for Cardiovascular System V: CT01:28

Imaging Studies for Cardiovascular System V: CT

542
Cardiac computed tomography (CT) scanning is an advanced cardiac imaging technique that utilizes CT technology, with or without intravenous (IV) contrast, to produce accurate cross-sectional virtual slices of specific areas of the heart, coronary circulation, and major blood vessels such as the aorta, pulmonary veins, and arteries. The computer processes these slices to generate three-dimensional images. Multidetector CT (MDCT) is a rapid form of CT scanning that captures multiple slices...
542

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Dataset effects outweigh algorithmic effects in determining fairness of healthcare machine learning.

NPJ digital medicine·2026
Same author

Validation of Automated Software for Guttae Quantification in Fuchs Endothelial Corneal Dystrophy.

Translational vision science & technology·2026
Same author

Wearable ECG and PPG for anxiety detection: a translational digital medicine perspective.

NPJ digital medicine·2026
Same author

Advances in automated fetal brain MRI segmentation and biometry: Insights from the FeTA 2024 challenge.

Medical image analysis·2026
Same author

ECG sonification methods for robust and generalizable clinical decision support.

NPJ digital medicine·2025
Same author

LesionSCynth: A simple parametric lesion synthesis method to improve spinal cord lesion segmentation in low-data scenarios.

Imaging neuroscience (Cambridge, Mass.)·2025

Related Experiment Video

Updated: Mar 26, 2026

3D Imaging of Soft-Tissue Samples using an X-ray Specific Staining Method and Nanoscopic Computed Tomography
07:01

3D Imaging of Soft-Tissue Samples using an X-ray Specific Staining Method and Nanoscopic Computed Tomography

Published on: October 24, 2019

10.4K

A sinogram denoising algorithm for low-dose computed tomography.

Davood Karimi1, Pierre Deman2, Rabab Ward3

  • 12366 Main Mall, Vancouver, V6T 1Z4, BC, Canada. karimi@ece.ubc.ca.

BMC Medical Imaging
|January 24, 2016
PubMed
Summary
This summary is machine-generated.

This study introduces a new algorithm to reduce noise in low-dose computed tomography (CT) scans. The method effectively denoises projection data, improving overall image quality for better patient health.

More Related Videos

Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
06:53

Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm

Published on: July 23, 2020

6.3K
Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph
05:32

Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph

Published on: February 21, 2025

771

Related Experiment Videos

Last Updated: Mar 26, 2026

3D Imaging of Soft-Tissue Samples using an X-ray Specific Staining Method and Nanoscopic Computed Tomography
07:01

3D Imaging of Soft-Tissue Samples using an X-ray Specific Staining Method and Nanoscopic Computed Tomography

Published on: October 24, 2019

10.4K
Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
06:53

Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm

Published on: July 23, 2020

6.3K
Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph
05:32

Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph

Published on: February 21, 2025

771

Area of Science:

  • Medical Imaging
  • Image Processing
  • Radiology

Background:

  • Reducing radiation dose in computed tomography (CT) is crucial for patient safety.
  • Low-dose CT scans result in noisy projection measurements, hindering image quality.
  • Effective denoising of projection data is essential for high-quality low-dose CT reconstruction.

Purpose of the Study:

  • To develop and evaluate a novel denoising algorithm for low-dose CT projection data.
  • To address the challenge of significant noise in low-dose CT scans.
  • To improve the quality of reconstructed CT images from noisy projections.

Main Methods:

  • A denoising algorithm maximizing data likelihood and gradient domain sparsity was proposed.
  • The method was adapted for normally-distributed noise, creating a locally adaptive scheme.
  • The algorithm was tested on simulated and real cone-beam CT projections, compared to existing methods.

Main Results:

  • The proposed algorithm demonstrated effective noise suppression in both simulated and real CT projections.
  • Denoising CT projections significantly enhanced reconstructed image quality, including noise reduction and improved spatial resolution.
  • Visual assessment confirmed the superior performance of the algorithm in improving image fidelity.

Conclusions:

  • The developed algorithm effectively suppresses high levels of quantum noise in CT projections.
  • This method serves as a valuable tool for achieving high-quality imaging in low-dose CT applications.
  • The findings support the use of this algorithm to improve diagnostic accuracy and patient safety in CT examinations.