Related Experiment Video
Updated: Mar 26, 2026

Simple and Rapid Method to Obtain High-quality Tumor DNA from Clinical-pathological Specimens Using Touch Imprint Cytology
Published on: March 21, 2018
DNA degradation in liquid-based cytology and its comparison with conventional smear
Wook Youn Kim1, Seo Young Oh2, Hyunkyung Kim1
1Department of Pathology, the Research Institute of Medical Science, Konkuk University School of Medicine, Seoul, Korea.
Background:
In fine needle aspiration biopsy (FNAB) of thyroid nodules, LBC is adopted in most of the hospitals and clinics in Korea for its convenience. BRAF mutation test has been introduced as an important ancillary test, but its applicability has not been completely proven with LBC samples.
Methods:
Five aspirates from thyroidectomy specimens were simultaneously processed into LBC and CS slides, in which BRAF mutation tests were performed using three primer sets with PCR products of 72, 164, and 226 base pairs (bp) at 6, 9, and 12 months after processing. In addition, BRAF mutation tests were performed in nine clinical samples that had been prepared by LBC or CS and stored for 3-5 years after processing.
Results:
At 9 months after processing, LBC failed to provide DNA of sufficient quality for PCR, whereas CS succeeded with primers for amplifying a 226 bp fragment. Furthermore, CS had successful amplification of DNA despite a delay of more than 1 year. The failure of DNA amplification in LBC was overcome by using primers to amplify shorter PCR products, suggesting that DNA degradation occurred in LBC. However, false positive or negative results were observed in primers for amplifying shorter size. The kind of preservative solutions used in LBC did not affect test results.
Conclusion:
LBC may have disadvantages in long-term DNA preservation because of its accelerated DNA degradation compared with alcohol-fixed CS. Using primers to amplify shorter size fragments might be helpful in mitigating loss of signal due to DNA degradation in LBC.
More Related Videos
06:04C. elegans Gonad Dissection and Freeze Crack for Immunofluorescence and DAPI Staining
Published on: September 16, 2022
09:58Preparation of Prokaryotic and Eukaryotic Organisms Using Chemical Drying for Morphological Analysis in Scanning Electron Microscopy SEM
Published on: January 7, 2019
Related Concept Videos
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Preparation of Samples for Electron Microscopy
Simple Staining Technique