Inspiratory Muscle Training as an Adjunct to the Treatment of Weaning Failure in Critically Ill Patients: A Practical Guide
Published on: January 30, 2026
A Pilot Randomized Trial Comparing Weaning From Mechanical Ventilation on Pressure Support Versus Proportional Assist
Karen J Bosma1, Brooke A Read, Mohammad J Bahrgard Nikoo
11London Health Sciences Centre, London, ON, Canada. 2Department of Medicine, The University of Western Ontario, London, ON, Canada.
Objectives:
Despite protocols incorporating spontaneous breathing trials, 31% of ICU patients experience difficult or prolonged weaning from mechanical ventilation. Nonfatiguing modes such as pressure support ventilation are recommended. Proportional assist ventilation provides assistance in proportion to patient effort, which may optimize weaning. However, it is not known how proportional assist ventilation performs relative to pressure support ventilation over a prolonged period in the complex ICU setting. The purpose of this study was to compare the physiologic and clinical performance (failure rate), safety, and feasibility of protocols using daily spontaneous breathing trial plus pressure support ventilation versus proportional assist ventilation until ventilation discontinuation.
Design:
Single-center, unblinded pilot randomized controlled trial.
Setting:
Medical-surgical ICU of a tertiary-care hospital.
Patients:
Adult patients intubated greater than 36 hours were randomized if they met eligibility criteria for partial ventilatory support, tolerated pressure support ventilation greater than or equal to 30 minutes, and either failed or did not meet criteria for a spontaneous breathing trial.
Interventions:
Patients were randomized to the pressure support ventilation or proportional assist ventilation protocol (PAV+, Puritan Bennett 840; Covidien, Boulder, CO). Both protocols used progressive decreases in level of assistance as tolerated, coupled with daily assessment for spontaneous breathing trials.
Measurements And Main Results:
Of 54 patients randomized, outcome data are available for 50 patients; 27 were randomized to receive proportional assist ventilation and 23 to receive pressure support ventilation. There were no adverse events linked to the study interventions, and protocol violations were infrequent. Recruitment was slower than projected (1.3 patients per month). The median (interquartile range) time from randomization to successful extubation was 3.9 days (2.8-8.4 d) on proportional assist ventilation versus 4.9 days (2.9-26.3 d) on pressure support ventilation (p = 0.39). Time to live ICU discharge was 7.3 days (5.2-11.4 d) on proportional assist ventilation versus 12.4 days (7.5-30.8 d) on pressure support ventilation (p = 0.03).
Conclusion:
This pilot study demonstrates the utility, safety, and feasibility of the weaning protocols and provides important information to guide the design of a future randomized controlled trial comparing weaning from mechanical ventilation on pressure support ventilation versus proportional assist ventilation.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation I: Indication and Settings
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement: