Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
The times they are a-changin': Two-dimensional aortic valve measurements differ throughout diastole
D Dickson1, D Caivano2, M Patteson1
1HeartVets, The Animal Hospital, Dursley, Gloucestershire, GL11 6AJ, UK.
Introduction:
Diastolic aortic valve measurements are used to obtain weight-independent cardiac ratiometric indices. However, whether clinically important variations in valve measurements occur during diastole remains undetermined.
Animals:
One hundred sixty-three dogs and 40 cats; a mixture of healthy animals and patients with heart disease.
Materials And Methods:
Aortic valve diameter and area were measured at three time-points: early diastole {AoMAX}, during the P-wave {AoP} and at end-diastole {AoMIN}. Measurement beat-to-beat variability was determined. Difference plots were generated for each measurement pair. Aortic measurements were compared by repeated measures analysis of variance.
Results:
In dogs, normalised aortic diameters showed a fixed bias of approximately 14% for AoMAX-AoMIN, 6% for AoMAX-AoP and 8% for AoP-AoMIN. In cats, the aortic diameter and area biases were all less than 2.5% and less than 7% respectively. AoMAX was the largest measurement in 78% patients and AoMIN was the smallest measurement in 73% patients. In dogs, AoMAX > AoP > AoMIN (p < 0.0001). Median within-patient measurement variability was 5% for linear dimensions and 8% for area measurements in dogs and 4.5% for linear and 10.4% for area in cats.
Discussion:
Aortic measurements in dogs differ significantly throughout diastole, with Ao(A)MAX > Ao(A)P > Ao(A)MIN. These differences could clinically impact cardiac ratiometric indices. The difference in cats is less than the within-patient measurement variability and unlikely to be of clinical significance.
Conclusions:
Operators should adopt a single diastolic time-point for measurement of the aorta to ensure consistency in measuring and reporting in echocardiography.
More Related Videos
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
12:12Echocardiographic Approaches and Protocols for Comprehensive Phenotypic Characterization of Valvular Heart Disease in Mice
Published on: February 14, 2017
Related Concept Videos
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Aortic Regurgitation I: Introduction
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...