Related Experiment Video
Updated: Mar 26, 2026

Pre-Implantation Genetic Testing for Aneuploidy on a Semiconductor Based Next-Generation Sequencing Platform
Published on: August 17, 2022
The importance of determining the limit of detection of non-invasive prenatal testing methods
Francesco Fiorentino1, Sara Bono1, Francesca Pizzuti1
1GENOMA Group, Molecular Genetics Laboratory, Via di Castel Giubileo, 11 00138, Rome, Italy.
Objective:
Several non-invasive prenatal testing (NIPT) methods, which analyze circulating fetal cell-free DNA (cfDNA) in maternal plasma, suggest a fetal fraction (FF) ≥ 4% for a reportable result, with the assumption that fetal aneuploidies may not be detectable at lower FF. This study determined the actual limit of detection (LOD) of a massively parallel sequencing-based NIPT method and evaluated its performance in testing samples with low FF.
Method:
An experimental model, involving the creation of artificial plasma mixtures with a final aneuploid FF ranging from 1% to 4%, simulated samples at different proportions of fetal cfDNA. We then analyzed 7103 blood samples, from pregnant women undergoing NIPT, to assess the impact of low FF on the performance of cfDNA testing.
Results:
Detection of common aneuploidies in samples with an FF as low as 2% is well within the ability of this technology. Of 105 pregnancies confirmed chromosomally abnormal, 25 (23.8%) involving a 2% < FF < 4% were consistently detected. These high-risk pregnancies would have not been identified using the suggested 4% FF cut-off.
Conclusion:
This study underscores the importance of determining the actual LOD for each specific NIPT methodology. It may reduce the incidence of test cancelations and shorten the time required for the diagnosis of aneuploidy. © 2016 John Wiley & Sons, Ltd.