Related Experiment Video
Updated: Mar 26, 2026

Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
[Clinical analysis of tricuspid valve replacement]
Jie Li1, Tingju Wei1, Donghai Liu1
1Department of Cardiovascular Surgery, First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China.
Objective:
To summarize the outcome of tricuspid valve replacement.
Methods:
A total of 28 patients (15 males and 13 females) underwent tricuspid valve replacement from March 2000 to February 2015 in the First Affiliated Hospital of Zhengzhou University were recruited. Among them, 16 patients were Ebstein's anomaly, 7 had rheumatic valve heart disease, 3 and 2 suffered from infective endocarditis and degenerative tricuspid lesions, respectively.
Results:
One patient died of multiple organ failure. Four patients were implanted permanent cardiac pacemaker because of third degree atrioventricular block occurring in the 5th day (2 patients) and in the 9th day (2 patients) after the operation, respectively. Twenty-seven patients were followed up from 1 month to 15 years. The prosthetic valves and permanent pacemakers worked well.
Conclusion:
Third degree of atrioventricular block, mostly appearing in early postoperative period, is the most common and severe complication of tricuspid valve replacement. The key point for prevention of damage is to accurately identify the anatomical relationship among the tricuspid valve, atrioventricular node, and conduction bundle.
More Related Videos
Related Concept Videos
Mitral Valve Prolapse II: Assessment and Management
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Mitral Stenosis II: Clinical features and Diagnostic Tests
Mitral Valve Prolapse I: Introduction
Mitral Regurgitation III: Medical Management
Mitral Regurgitation I: Introduction