Related Experiment Video
Updated: Mar 26, 2026

Doppler Optical Coherence Tomography of Retinal Circulation
Published on: September 18, 2012
Intravascular optical coherence tomography for the evaluation of arterial bifurcations covered by flow diverters
Christina Iosif1,2, Suzana Saleme1,2, Sebastien Ponsonnard3
1Interventional Neuroradiology Department, Dupuytren University Hospital (CHU Limoges), Limoges, France.
Background And Objective:
Due to its high spatial resolution, intravascular optical coherence tomography (OCT) has been used as a valid method for in vivo evaluation of several types of coronary stents at straight lumen and bifurcation sites. We sought to evaluate its effectiveness for flow diverting stents deployed in arterial bifurcation sites involving jailing of a side branch.
Methods:
Four large white swine were stented with flow diverting stents covering the right common carotid artery-ascending pharyngeal artery bifurcation. After 12 weeks of follow-up the animals were evaluated by digital subtraction angiography and intravascular OCT and subsequently sacrificed. Neointimal thickness on the parent arteries and the free segments of the stent were measured. The stented arteries were harvested and underwent scanning electron microscopy (SEM) imaging. Ostia surface values were measured with OCT three-dimensional (3D) reconstructions and SEM images.
Results:
All endovascular procedures and OCT pullback runs were feasible. Stent apposition was satisfactory on the immediate post-stent OCT reconstructions. At 12-week controls, all stents and jailed branches were patent. Mean neointimal thickness was 0.11±0.04 mm on the free segments of the stent. The mean ostia surface at 12 weeks was 319 750±345 533 μm2 with 3D-OCT reconstructions and 351 198±396 355 μm2 with SEM image-derived calculations. Good correlation was found for ostia surface values between the two techniques; the values did not differ significantly in this preliminary study.
Conclusions:
Intravascular OCT appears to be a promising technique for immediate and follow-up assessment of the orifice of arterial branches covered by flow diverting stents.
More Related Videos
12:00Evaluation of a Novel Laser-assisted Coronary Anastomotic Connector - the Trinity Clip - in a Porcine Off-pump Bypass Model
Published on: November 24, 2014
13:07Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
Published on: January 15, 2022
Related Concept Videos
Imaging Studies VII: Vascular Imaging
Overview of Systemic Arteries
Systemic circulation is the part of the cardiovascular system that carries oxygenated blood away from the heart to the body's tissues and returns deoxygenated blood back to the...