Related Experiment Video
Updated: Sep 25, 2026

Direct Pressure Monitoring Accurately Predicts Pulmonary Vein Occlusion During Cryoballoon Ablation
Published on: February 26, 2013
Increased left atrial pressure predicts recurrence following successful cryoablation for atrial fibrillation with
Banu Evranos1, Duygu Kocyigit2, Kadri Murat Gurses3
1Department of Cardiology, Faculty of Medicine, Hacettepe University, 06100, Ankara, Sihhiye, Turkey. banu.evranos@yahoo.com.
Purpose:
Several studies have demonstrated that left ventricular diastolic dysfunction (LVDD) and left atrial pressure (LAP), as a surrogate marker of LVDD, were associated with atrial fibrillation (AF) recurrence following radiofrequency catheter ablation (RFCA) for AF. In this study, we aimed to investigate the individual impact of several left ventricular diastolic function parameters on outcomes of cryoablation for paroxysmal AF using second-generation cryoballoon.
Methods:
One hundred seventy patients who were scheduled for cryoablation with second-generation cryoballoon were included in this prospective study. All patients underwent comprehensive transthoracic and transesophageal echocardiographic examinations during sinus rhythm a day before catheter ablation. LAP was measured via transseptal sheath at the beginning of the ablation procedure.
Results:
One hundred seventy patients (57.09 ± 11.80 years, 47.06 % male) were involved in the study. At a median follow-up of 19 months, when blanking period of 3 months was considered, freedom from AF after a single ablation procedure was 84.71 %. Patients with AF recurrence had significantly greater left atrial volume index (LAVI) (p = 0.005) and LAP (p < 0.001). Patients with AF recurrence had lower septal e' wave (p = 0.013), and higher E/e' ratio (p = 0.014). LAVI (p = 0.007) and LAP (p = 0.006) were independent predictors of AF recurrence. A cut-off value of 13.50 mmHg for LAP measured during the procedure was associated with a sensitivity and specificity of 80.8 and 84.7 % (p = 0.005) for predicting AF recurrence.
Conclusions:
Pre-procedural LAVI and procedural LAP measurement have clinical importance in predicting AF recurrence in patients undergoing cryoablation with second-generation cryoballoon. Effectiveness of cryoablation is reduced in patients with greater LAVI and LAP.
More Related Videos
10:46Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
08:00Reduction of Iatrogenic Atrial Septal Defects with an Anterior and Inferior Transseptal Puncture Site when Operating the Cryoballoon Ablation Catheter
Published on: June 15, 2015