Implantation depth measured by 64-slice computed tomography is associated with permanent pacemaker requirement
Jürgen Kammler1, Hermann Blessberger1, Franz Fellner2
1Linz General Hospital, 1st Medical Department - Cardiology, Johannes Kepler University School of Medicine, Linz, Austria.
Background:
Patients undergoing transcatheter aortic valve implantation (TAVI) are at increased risk for post-interventional conduction disturbances leading to pacemaker (PM) implantation. We analyzed the association between implantation depth within the left ventricular outflow tract (LVOT), measured by 64-slice computed tomography (CT), and 'index electrocardiographic (ECG) changes' (new onset atrioventricular-block grade II or III or left bundle branch block with PR interval prolongation >200ms).
Methods:
We evaluated patients who underwent TAVI with the Core Valve(®) revalving system (Medtronic, Minneapolis, MN, USA) for treatment of severe aortic stenosis at our department. Patients with a prior PM implantation and patients for whom no CT scan was available after 3 months were excluded from analysis. We assessed implantation depth of the prosthesis within the LVOT as possible risk factors for the development of post-interventional 'index ECG changes' resulting in PM implantation and compared it with individual patient data as well as echocardiographic and electrocardiographic parameters.
Results:
The final study cohort comprised 53 patients for whom a 64-slice CT scan was available (mean age 81.7±5.1 years, 36% male). Twenty-eight of these finally underwent PM implantation due to 'index ECG changes' within the first 48hours after TAVI. Univariate logistic regression analysis could identify implantation depth of the prosthesis as the only significantly correlated risk factor for PM need in our cohort (OR 1.27, 95% CI: 1.08-1.51, p=0.004). A cut-off value of 6mm predicted this need with a sensitivity of 89% and specificity of 40%.
Conclusion:
Implantation depth of the Core Valve(®) into the LVOT was associated with post-procedural PM requirement. Thereby, a cut-off value of 6mm, as measured by 64-slice CT, proved useful to define patients at risk for PM requirement.
More Related Videos
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
06:04Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation
Published on: August 8, 2025
Related Concept Videos
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization II: Right Heart Catheterization
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Cardiac Catheterization I: Pre-Procedure Overview