Interference of anesthetics in blood alcohol analysis by HS-GC-FID: A case report
C Monteiro1, P Proença1, C Tavares2
1National Institute of Legal Medicine and Forensic Sciences, Centre Branch, Largo da Sé Nova, Coimbra 3000-213, Portugal; CENCIFOR, Forensic Sciences Centre, Largo da Sé Nova, Coimbra 3000-213, Portugal.
Abstract:
One of the techniques most widely used in ethanol analysis in forensic laboratories is undoubtedly the headspace gas chromatography with flame-ionization detection (HS-GC-FID) since the determination of this substance is carried out directly, without the need for additional purification procedures, which leads to increased productivity. This is a very important factor due to the high number of alcohol analysis requested to these laboratories. The presence of other volatile substances can cause a problem given the fact that they can be interferents in ethanol analysis by HS-GC-FID, which can have legal consequences related with driving under the influence of alcohol. The authors report a case of a routine analysis by HS-GC-FID for the determination of ethanol of a driver who has suffered an accident in which the use of two chromatographic columns with different polarities was essential to obtain an unequivocally identification of this substance in presence of an interfering volatile anesthetic administered in the hospital. The method was validated according to international recommendations before being introduced into routine laboratory in terms of selectivity, limits of detection (LOD), limits of quantification (LOQ), linearity, repeatability, intermediate precision, accuracy, robustness and carryover.
Related Concept Videos
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Atomic Emission Spectroscopy: Interference