Related Experiment Video
Updated: Mar 26, 2026

Intra-Operative Neural Monitoring of Thyroid Surgery in a Porcine Model
Published on: February 11, 2019
Intermittent intraoperative nerve monitoring in thyroid reoperations: Preliminary results of a randomized,
Hu Hei1, Bin Zhou1, Jianwu Qin1
1Department of Thyroid and Neck, The Affiliated Cancer Hospital of Zhengzhou University, Henan Cancer Hospital, Zhengzhou, China.
Background:
The purpose of this study was to evaluate whether intermittent intraoperative nerve monitoring (IONM) could reduce the incidence of recurrent laryngeal nerve (RLN) paralysis in thyroid reoperations.
Methods:
Enrolled patients were randomly assigned into the nerve integrity monitor (NIM) group and the control group.
Results:
The incidence of temporary RLN paralysis and permanent RLN paralysis was 12.2% and 4.9% in the NIM group compared with 7.0% and 2.3% in the control group (p = .658 and p = .966, respectively). The incidence of surgeon-related paralysis, tumor-related paralysis, and scar-related paralysis was 4.9%, 7.3%, and 4.9% in the NIM group compared with 4.7%, 2.3%, and 2.3% in the control group, respectively (p = 1, p = .575, and p = .966, respectively).
Conclusion:
Intermittent IONM could not provide additional benefits to reduce the incidence of temporary RLN paralysis and permanent RLN paralysis in thyroid reoperations. It could not reduce the incidence of paralysis caused by unintentional injuries. © 2016 Wiley Periodicals, Inc. Head Neck 38: E1993-E1997, 2016.
More Related Videos
05:25Identification and Protection of the Recurrent Laryngeal Nerve during Transoral Robotic Thyroidectomy
Published on: October 24, 2025
11:46Investigation of the Electrophysiological and Thermographic Safety Parameters of Surgical Energy Devices During Thyroid and Parathyroid Surgery in a Porcine Model
Published on: October 13, 2022