Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy oSLO and Optical Coherence Tomography OCT
Published on: August 4, 2018
Iterative re-weighted approach to high-resolution optical coherence tomography with narrow-band sources
Abstract:
Optical coherence tomography (OCT) is a non-invasive optical imaging modality capable of high resolution imaging of internal tissue structures. It is widely believed that the high axial resolution in OCT systems requires a wide-bandwidth light source. As a result, often the potential advantages of narrow-bandwidth sources (in terms of cost and/or imaging speed) are understood to come at the cost of significant reduction in imaging resolution. In this paper, we argue that this trade-off between resolution and speed is a shortcoming imposed by the-state-of-the-art A-scan reconstruction algorithm, Fast Fourier Transform, and can be circumvented through use of alternative processing methods. In particular, we investigate the shortcomings of the FFT as well as previously proposed alternatives and demonstrate the first application of an iterative regularized re-weighted l(2) norm method to improve the axial resolution of fast scan rate OCT systems in the narrow-bandwidth imaging conditions. We validate our claims via experimental results generated from a home-built OCT system used to image layered phantom and in vivo data. Our results rely on new, sophisticated signal processing algorithms to generate higher precision (i.e., higher resolution) OCT images at correspondingly fast scan rates. In other words, our work demonstrates the feasibility of simultaneously more reliable and more comfortable medical imaging systems for patients by reducing the overall scan time, without sacrificing image quality.
More Related Videos
Related Concept Videos
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Super-resolution Fluorescence Microscopy
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...