Introduction:
Robotic surgery provides an alternative option for a minimal access approach. It provides a stable platform with high definition three-dimensional views and improved access, which enhances the capabilities for precise dissection in a narrow surgical field. These distinctive features have made it an attractive option for colorectal surgeons.
Aim:
The aim of this study was to present a standardised technique for single-docking robotic rectal resection and to analyse clinical outcomes of the first 100 robotic rectal procedures performed in a single centre between May 2013 and April 2015.
Method:
Prospectively collected data related to 100 consecutive patients who underwent single-docking robotic rectal surgery was analysed for surgical and oncological outcomes.
Results:
Sixty-six patients were male, the median age was 67 years (range-24-92). Eighteen patients had neo-adjuvant chemoradiotherapy whilst 23 patients had BMI >30. Procedures performed included anterior resection (n = 74), abdominoperineal resection (n = 10), completion proctectomy (n = 9), restorative proctectomy with ileal pouch-anal anastomosis (IPAA) (n = 5) and Hartmann's procedure (n = 2). The median operating time was 240 min (range-135-456), and median blood loss was 10 ml (range 0-200). There was no conversion or intra-operative complication. Median length of stay was 7 days (range, 3-48) and readmission rate was 12 %. Thirty-day mortality was zero. Postoperatively, two patients had an anastomotic leak whilst two had small bowel obstruction. The median lymph node harvest was 18 (range, 6-43).
Conclusion:
The single-docking robotic technique should be considered as an alternative option for rectal surgery. This approach is safe and feasible and in our study it has demonstrated favourable clinical outcomes.