Sampling and error analysis of radial symmetric interpolation for fast hologram generation

Applied Optics
|February 3, 2016
PubMed

Related Concept Videos

Reconstruction of Signal using Interpolation01:10

Reconstruction of Signal using Interpolation

Signal processing techniques are essential for accurately converting continuous signals to digital formats and vice versa. When a continuous signal is sampled with a period T, the resulting sampled signal exhibits replicas of the original spectrum in the frequency domain, spaced at intervals equal to the sampling frequency. To handle this sampled signal, a zero-order hold method can be applied, which creates a piecewise constant signal by retaining each sample's value until the next...
831
Aliasing01:18

Aliasing

Accurate signal sampling and reconstruction are crucial in various signal-processing applications. A time-domain signal's spectrum can be revealed using its Fourier transform. When this signal is sampled at a specific frequency, it results in multiple scaled replicas of the original spectrum in the frequency domain. The spacing of these replicas is determined by the sampling frequency.
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original...
767
Sampling Theorem01:15

Sampling Theorem

In signal processing, the analysis of continuous-time signals, denoted as x(t), often involves sampling techniques to convert these signals into discrete-time signals. This process is essential for digital representation and manipulation. A critical component in sampling is the train of impulses, characterized by the sampling interval and the sampling frequency. The relationship between these parameters and the original signal's properties dictates the success of the sampling process.
1.5K
Sampling Methods: Overview01:06

Sampling Methods: Overview

A sample refers to a smaller subset representative of a larger population. In analytical chemistry, studying or analyzing an entire population is often impractical or impossible. Therefore, samples are used to draw inferences and generalize the whole population. The sampling method selects individuals or items from a population to create a sample. Standard sampling methods include random, judgemental, systematic, stratified, and cluster sampling. 
In analytical chemistry, the choice of...
3.9K
NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
1.1K