Real-time 3D digital image correlation method and its application in human pulse monitoring
Abstract:
In industrial measurements and online monitoring, full-field and high-efficiency deformation analysis has been increasingly important and highly demanded in recent years. In this paper, a fast three-dimensional digital image correlation (3D-DIC) method was proposed to implement real-time measurement. Two improvements were suggested to accelerate the computation speed without sacrificing the accuracy. First, an efficient inverse compositional Gauss-Newton (IC-GN) algorithm was developed to avoid redundant computation. Moreover, a seed point-based parallel method was extended for 3D-DIC to achieve parallel computation and faster convergence speed. The detailed process of the real-time measurement using the proposed method was also introduced. Benefiting from the efficient IC-GN algorithm and parallel processing software we developed, full-field, real-time 3D deformation monitoring was realized at a frame rate of 10 frames/s with resolution of 5000 points per frame. For validation, the displacement field of a four-point bending beam was determined by the real-time 3D-DIC. As an application, the real-time human pulse diagnosis was also performed based on the presented technique. Experimental results verify that the proposed real-time 3D-DIC is practicable and effective for traditional Chinese medicine.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Special considerations while measuring pulse
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps: