Related Experiment Video
Updated: Mar 26, 2026

Highly Sensitive and Rapid Fluorescence Detection with a Portable FRET Analyzer
Published on: October 1, 2016
Rapid and label-free detection of ochratoxin A and aflatoxin B1 using an optical portable instrument
Fabiana Arduini1, Daniela Neagu1, Valeria Pagliarini2
1Dipartimento di Scienze e Tecnologie Chimiche, Università di Roma Tor Vergata, Via della Ricerca Scientifica, 00133 Rome, Italy; Consorzio Interuniversitario Biostrutture e Biosistemi "INBB", Viale Medaglie d'Oro 305, Rome, Italy.
Abstract:
In this study, we report a novel assay for the combined on site detection of aflatoxin B1 (AFB1) and ochratoxin A (OTA), through a colorimetric biosensing system for AFB1 and a fluorimetric detection for OTA, exploiting the capability of the portable fibre optic spectrometer to perform both analyses. AFB1 was detected using the acetylcholinesterase (AChE) enzyme that is inhibited by this toxin, and the degree of inhibition was quantified by the Ellman's spectrophotometric method, obtaining a detection limit of 10 µg L(-1). OTA quantification was performed by monitoring its intrinsic fluorescence in methanol, reaching a detection limit of 0.1 µg L(-1). In order to successfully apply the analytical tool in the food analysis, immunoaffinity columns were used. Clean-up and quantification of both AFB1 and OTA in millet samples was obtained by HPLC-dedicated AflaOchra-Test HPLC™ (Vicam™) and Afla-OtaCLEAN™ (LC-Tech) immunoaffinity columns, followed by absorption/fluorescence detection. Millet samples which were fortified with both OTA (50 µg kg(-1)) and AFB1 (20 µg kg(-1)), gave recovery values of 100 ± 6% for OTA, and 110 ± 10% for AFB1, using AflaOchra-Test HPLC™. Single OTA clean-up and quantification in wine samples was obtained, using an OchraTest immunoaffinity column (Vicam™), reaching a detection limit of 0.3 µg L(-1) and recovery values between 80% and 120%. These results demonstrated the possibility of employing a single clean-up and a cost-effective, and easy to use analytical system for both AFB1 and OTA detection at µg kg(-1) (ppb) level. Furthermore, in the case of positive samples, they could be analysed further, using standard chromatographic procedures, without any additional clean-up step, since the same extraction procedure of standard method is proposed in our method.
More Related Videos
09:51TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples
Published on: September 19, 2025
05:18A Rapid and Chemical-free Hemoglobin Assay with Photothermal Angular Light Scattering
Published on: December 7, 2016