Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Two-Compartment Open Model: Extravascular Administration01:12

Two-Compartment Open Model: Extravascular Administration

801
The two-compartment model for extravascular administration represents a drug's absorption and distribution process. It features a central compartment, where the drug is first absorbed, and a peripheral compartment, which illustrates the drug's distribution throughout the body. The rate of change in drug concentration in the central compartment is calculated by three exponents: absorption, distribution, and elimination.
The absorption exponent (ka) indicates the speed at which the drug...
801
Physiological Pharmacokinetic Models: Blood Flow-Limited Versus Diffusion-Limited Models00:57

Physiological Pharmacokinetic Models: Blood Flow-Limited Versus Diffusion-Limited Models

434
Physiological pharmacokinetic models, often called flow-limited or perfusion models, typically assume a swift drug distribution between tissue and venous blood, creating a rapid drug equilibrium. This premise is based on the idea that drug diffusion is extremely fast, and the cell membrane presents no barrier to drug permeation. In this scenario, where no drug binding occurs, the drug concentration in the tissue equals that of the venous blood leaving the tissue. This greatly simplifies the...
434

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Magnetic Resonance Imaging at 14 Tesla of Prostate Biopsies Obtained after Prostatectomy.

NMR in biomedicine·2026
Same author

Correction to: Preoperative risk assessment of endometrial cancer using histogram analysis of weighted and quantitative MRI images.

Abdominal radiology (New York)·2026
Same author

Self-Supervised Deep Learning Framework for Rician Distribution Based Denoising and Modeling of Multi-b Prostate Diffusion MRI.

Magnetic resonance in medicine·2026
Same author

Optimization of Diffusion MRI With Consideration of the Signal Decay in Biological Tissues.

Magnetic resonance in medicine·2026
Same author

Motion-compensated diffusion encoding gradients for segmented thick-slab 3D magnetic resonance diffusion-weighted imaging of the brain.

Medical physics·2026
Same author

Evidence for the Existence of Two Opposing Pulse Waves in Retinal Vein Segments Within the Optic Disc.

Investigative ophthalmology & visual science·2025
Same journal

Resveratrol Mitigates Noise-Induced Cochlear Damage and Delays Hearing Loss in Wistar Rats.

BioMed research international·2026
Same journal

RETRACTION: Green Fabrication of Silver Nanoparticles Using Euphorbia Serpens Kunth Aqueous Extract, their Characterization, and Investigation of its in Vitro Antioxidative, Antimicrobial, Insecticidal, and Cytotoxic Activities.

BioMed research international·2026
Same journal

Predictors of Prolonged Hospital Length of Stay in Patients With Odontogenic Infections in Ghana.

BioMed research international·2026
Same journal

Traditional Chinese Medicine Bone-Setting Techniques Research Progress for the Treatment of Knee Osteoarthritis.

BioMed research international·2026
Same journal

RETRACTION: miR-375 Inhibits the Proliferation and Invasion of Nasopharyngeal Carcinoma Cells by Suppressing PDK1.

BioMed research international·2026
Same journal

Exploring the Therapeutic Potential of Nobiletin in Nonsmall Cell Lung Cancer.

BioMed research international·2026
See all related articles

Related Experiment Video

Updated: Mar 26, 2026

Image Processing Protocol for the Analysis of the Diffusion and Cluster Size of Membrane Receptors by Fluorescence Microscopy
12:15

Image Processing Protocol for the Analysis of the Diffusion and Cluster Size of Membrane Receptors by Fluorescence Microscopy

Published on: April 9, 2019

9.3K

Optimal Experiment Design for Monoexponential Model Fitting: Application to Apparent Diffusion Coefficient Imaging.

Mohammad Alipoor1, Stephan E Maier2, Irene Yu-Hua Gu1

  • 1Department of Signals and Systems, Chalmers University of Technology, 41296 Gothenburg, Sweden.

Biomed Research International
|February 4, 2016
PubMed
Summary
This summary is machine-generated.

This study introduces a D-optimal design for fitting the monoexponential model in biomedical imaging. This new method improves the accuracy and precision of parameter estimation in applications like apparent diffusion coefficient (ADC) imaging.

More Related Videos

Diffusion Imaging in the Rat Cervical Spinal Cord
10:46

Diffusion Imaging in the Rat Cervical Spinal Cord

Published on: April 7, 2015

12.3K
Single-Molecule Tracking Microscopy - A Tool for Determining the Diffusive States of Cytosolic Molecules
10:20

Single-Molecule Tracking Microscopy - A Tool for Determining the Diffusive States of Cytosolic Molecules

Published on: September 5, 2019

8.9K

Related Experiment Videos

Last Updated: Mar 26, 2026

Image Processing Protocol for the Analysis of the Diffusion and Cluster Size of Membrane Receptors by Fluorescence Microscopy
12:15

Image Processing Protocol for the Analysis of the Diffusion and Cluster Size of Membrane Receptors by Fluorescence Microscopy

Published on: April 9, 2019

9.3K
Diffusion Imaging in the Rat Cervical Spinal Cord
10:46

Diffusion Imaging in the Rat Cervical Spinal Cord

Published on: April 7, 2015

12.3K
Single-Molecule Tracking Microscopy - A Tool for Determining the Diffusive States of Cytosolic Molecules
10:20

Single-Molecule Tracking Microscopy - A Tool for Determining the Diffusive States of Cytosolic Molecules

Published on: September 5, 2019

8.9K

Area of Science:

  • Biomedical imaging
  • Quantitative imaging
  • Medical physics

Background:

  • The monoexponential model is crucial for quantitative biomedical imaging, particularly in apparent diffusion coefficient (ADC) imaging and pharmacokinetic studies.
  • Optimal experiment design is essential for accurate monoexponential model fitting, especially for detecting malignant tissues using ADC imaging.

Purpose of the Study:

  • To propose a novel experiment design method for monoexponential model fitting based on D-optimal design principles.
  • To evaluate the performance of the D-optimal design in apparent diffusion coefficient (ADC) imaging across various parameters.

Main Methods:

  • Developed a D-optimal design strategy by minimizing the determinant of the covariance matrix of estimated parameters.
  • Applied the D-optimal design to ADC imaging and assessed its performance across a range of input variables.
  • Utilized Monte Carlo simulations to compare the D-optimal design with existing methods.

Main Results:

  • The proposed D-optimal design is independent of specific imaged quantities, offering broader applicability.
  • Demonstrated consistent performance of the D-optimal design in ADC imaging for diverse parameters, including imaged parameters, measurement counts, and b-value ranges.
  • Monte Carlo simulations confirmed that the D-optimal design yields superior accuracy and precision in parameter estimation compared to existing methods.

Conclusions:

  • The D-optimal design represents a significant advancement for experiment design in monoexponential model fitting within quantitative biomedical imaging.
  • This method enhances the reliability and accuracy of parameter estimation in ADC imaging, potentially improving diagnostic capabilities for malignant tissues.