Related Experiment Video
Updated: Mar 26, 2026

Endotracheal Intubation in Mice via Direct Laryngoscopy Using an Otoscope
Published on: April 5, 2014
Direct Versus Video Laryngoscopy Using the C-MAC for Tracheal Intubation in the Emergency Department, a Randomized
Brian E Driver1, Matthew E Prekker1,2, Johanna C Moore1
1Department of Emergency Medicine, Hennepin County Medical Center, Minneapolis, MN.
Background:
Direct laryngoscopy (DL) has long been the most common approach for emergency endotracheal intubation, although the use of video laryngoscopy (VL) is becoming more widespread. Current observational data suggest that VL has higher first-pass success, although randomized trials are lacking.
Objectives:
The objective was to compare first-pass success in patients undergoing emergency intubation with DL or VL using a C-MAC device.
Methods:
This was an open-label, prospective, randomized, controlled trial in an academic emergency department of patients undergoing emergency intubation with a plan of DL for the first attempt. Patients were randomly assigned in a 1:1 ratio to either DL or VL using a C-MAC device for the first intubation attempt. The primary outcome was first-pass success. Secondary outcomes included time to intubation, development of aspiration pneumonia, and hospital length of stay (LOS). The study was registered at Clinicaltrials.gov, number NCT01710891.
Results:
A total of 198 patients were enrolled and intubated with either DL (n = 95) or VL (n = 103). First-attempt success was 86 and 92% for the DL and VL groups, respectively (difference = -5.9%, 95% confidence interval = -14.5% to 2.7%, p = 0.18). Time to intubation, rates of aspiration pneumonia, and hospital LOS were not different between the two groups.
Conclusions:
In patients undergoing emergency intubation in whom DL was planned for the first attempt, we did not detect a difference between VL or DL using the C-MAC device in first-pass success, duration of intubation attempt, aspiration pneumonia, or hospital LOS.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes: