Comparison of changes in vertical dimension between compression and injection molded complete dentures
1Department of Prosthodontics, Medical University of South Carolina, College of Dental Medicine, Charleston.
The Journal of Prosthetic Dentistry
|December 1, 1989
Summary
The SR-Ivocap injection system for complete dentures significantly reduced vertical dimension changes compared to conventional compression molding. This suggests the injection method may eliminate the need for laboratory remount procedures.
Area of Science:
- Dental prosthetics
- Materials science in dentistry
Background:
- Conventional compression molding is a widely used technique for complete denture fabrication.
- Processing errors, such as changes in vertical dimension, can occur during conventional denture processing.
- The SR-Ivocap injection system offers an alternative processing method for complete dentures.
Purpose of the Study:
- To compare the accuracy of vertical dimension maintenance between conventional compression molding and the SR-Ivocap injection system for complete dentures.
- To evaluate the impact of processing methods on dimensional stability in complete denture fabrication.
Main Methods:
- Thirty patients received complete dentures, with 15 processed via conventional compression molding and 15 via the SR-Ivocap injection system.
- Changes in vertical dimension were measured using a dial indicator at the incisal guide pin before and after processing.
- Statistical analysis was performed using t-tests to determine significant differences between the two methods.
Main Results:
- A highly significant difference in vertical dimension changes was observed between the two processing methods.
- Conventional compression molding showed processing changes consistent with previous studies.
- The SR-Ivocap injection system resulted in minimal to no change in vertical dimension (pin opening).
Conclusions:
- The SR-Ivocap injection system demonstrates superior accuracy in maintaining vertical dimension during complete denture processing compared to conventional methods.
- The minimal dimensional changes associated with the injection system suggest that laboratory remount procedures may be rendered unnecessary, potentially streamlining the fabrication process.