Related Experiment Video
Updated: Mar 26, 2026

A Silicosis Mouse Model Established by Repeated Inhalation of Crystalline Silica Dust
Published on: January 6, 2023
Relationship of cumulative dust exposure dose and cumulative abnormal rate of pulmonary function in coal mixture
Qing-Zeng Qian1, Xiang-Ke Cao2, Qing-Qiang Qian3
1College of Public Health, North China University of Science and Technology, Tangshan, People's Republic of China.
Abstract:
To investigate the dose-response relationship between cumulative dust exposure (CDE) and cumulative abnormal rate of pulmonary function in coal mixture workers. Three hundred and twenty eight coal mixture workers (exposed group) and 169 nondust-exposed workers (control group) were recruited. Basic information data were collected and pulmonary function tests were performed. Pulmonary function was compared between the two groups after comparing smoking behaviors. Pulmonary function indices [forced vital capacity in 1 second after full inspiration (FVC)%, forced expiratory volume (FEV)1%, and FEV1/FVC%] were compared among groups stratified by service length (exposure duration). The relationship between CDE dose and cumulative abnormal rate of pulmonary function in coal mixture workers was analyzed. Abnormal rate of pulmonary function in the exposed group (35.1%) was significantly higher than the control group (10.1%; p < 0.001); FVC%, FEV1%, and FEV1/FVC% in the exposed group decreased significantly compared with the control group (all p < 0.05). Differences in FVC%, FEV1%, and FEV1/FVC% among coal mixture workers stratified by exposure duration in the exposed group were statistically significant (all p < 0.05). The discernible increase in the cumulative abnormal rate was observed, from ≥ 1000 mg/m(3)·years group to ≥ 1700 mg/m(3)·years group. Correlation analysis revealed a positive correlation between the CDE dose and the cumulative abnormal rate of pulmonary function. Higher abnormal pulmonary function rate was found among coal mixture workers, characterized by decreased pulmonary function indices. Our results suggested a positive relationship between CDE dose and cumulative abnormal pulmonary function rate, and a rapid increase in cumulative abnormal rate within a certain range of CDE dose. A lower limit value of 1000 mg/m(3)·years has reference significance.
More Related Videos
09:29An Air-liquid Interface Bronchial Epithelial Model for Realistic, Repeated Inhalation Exposure to Airborne Particles for Toxicity Testing
Published on: May 13, 2020
08:17Generation of a Chronic Obstructive Pulmonary Disease Model in Mice by Repeated Ozone Exposure
Published on: August 25, 2017
Related Concept Videos
Chronic Obstructive Pulmonary Disease-I: Introduction
Relative Risk
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Respiratory System Abnormal Finding I: Inspection and Percussion
Inspection Findings
During an inspection, several findings may suggest the presence of respiratory distress or disease. Pursed-lip breathing, where exhalation is slowed by...
Statistical Methods for Analyzing Epidemiological Data