Cardiac rhythm management device (CRMD) implantation has low complication rates. Complications, though infrequent, can increase hospital stay and costs, varying by the nature of the event.
Area of Science:
- Cardiology
- Medical Devices
- Health Outcomes Research
Background:
- Cardiac rhythm management devices (CRMDs) are clinically effective for heart rhythm disorders.
- Safety and complication rates during CRMD implantation are not well-established.
- This study aimed to determine complication rates and associated healthcare utilization.
Purpose of the Study:
- To evaluate the incidence of complications following cardiac rhythm management device implantation.
- To estimate the additional hospital stay and costs linked to managing these complications.
Main Methods:
- A prospective study of 464 consecutive patients undergoing CRMD implantation over one year.
- Follow-up was conducted for two years, with data analyzed for 398 patients (796 patient-years).
Main Results:
- Low complication rates were observed: 2.99% for initial pacemaker (PM) implantations and 0.85% for PM replacements.
- No complications occurred with implantable cardioverter-defibrillator (ICD) implantations or replacements.
- Complications led to an average of 7 additional hospital days and $17,411 in direct costs.
Conclusions:
- CRMD implantation, both initial and replacement, demonstrates relatively low complication rates.
- The duration of hospitalization and associated costs are contingent upon the specific complication encountered.
Introduction:
Cardiac rhythm management devices (CRMDs) have proven their clinical effectiveness for patients with heart rhythm disorders. Little is known about safety and complication rates during the implantation of these devices. This study demonstrated the complication rates related to CRMD implantation, and estimated the additional hospital stay and cost associated with the management of complications.
Methods:
During a period of one year, a total of 464 consecutive recipients underwent CRMD implantation and were followed for 2 years. Finally, data were analyzed for 398 patients who completed the two-year follow up, resulting in a total of 796 patient-years.
Results:
Of the 201 patients with initial pacemaker (PM) implantations, 6 (2.99%) had seven complications (5 patients had lead dislodgement, 1 of them twice), and 1 patient developed pocket infection. Of the 117 PM replacements, 1 (0.85%) patient developed a complication (pocket erosion). Two patients with complications (1 with an initial PM and 1 with a replacement) died before completing the follow up for reasons unrelated to cardiac causes. There were no complications in either initial implantations (69 patients) or replacements (11 patients) of implantable cardioverter-defibrillators. The average prolongation of the hospital stay was 7 days, ranging from 1 to 35 days, resulting in 17,411 of total additional direct hospital costs.
Conclusion:
This study found relatively low rates of complications in patients undergoing CRMD implantation, initial or replacement, in our center, compared with other studies. The additional hospitalization days and costs attributable to these complications depend on the nature of the complication.
More Related Videos
06:10Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
Related Concept Videos
Dysrhythmias VI: Management of Dysrhythmias
Dysrhythmias VII: Nursing Management of Dysrhythmias
Cardiomyopathy V: Interprofessional Care
Cardiomyopathy II: Dilated Cardiomyopathy
Heart Failure VI: Adjunct Therapies
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...