Related Experiment Video
Updated: Mar 26, 2026

In Vivo, Percutaneous, Needle Based, Optical Coherence Tomography of Renal Masses
Published on: March 30, 2015
Prostate cancer diagnosis by optical coherence tomography: First results from a needle based optical platform for
Berrend G Muller1, Daniel M de Bruin2,3, Martin J Brandt3
1Department of Urology, Academic Medical Center, University of Amsterdam, Meibergdreef 9, 1105, AZ Amsterdam Z.O., The Netherlands. b.g.muller@amc.uva.nl.
Abstract:
The diagnostic accuracy of Optical Coherence Tomography (OCT) based optical attenuation coefficient analysis is assessed for the detection of prostate cancer. Needle-based OCT-measurements were performed on the prostate specimens. Attenuation coefficients were determined by an earlier described in-house developed software package. The mean attenuation coefficients (benign OCT data; malignant OCT data; p-value Mann-Whitney U test) were: (3.56 mm(-1) ; 3.85 mm(-1) ; p < 0.0001) for all patients combined. The area under the ROC curve was 0.64. In order to circumvent the effect of histopathology mismatching, we performed a sub-analysis on only OCT data in which tumor was visible in two subsequent histopathological prostate slices. This analysis could be performed in 3 patients. The mean attenuation coefficients (benign OCT data; malignant OCT data; p-value Mann-Whitney U test) were: (3.23 mm(-1) ; 4.11 mm(-1) ; p < 0.0001) for all patients grouped together. The area under the ROC curve was 0.89. Functional OCT of the prostate has shown to differentiate between cancer and healthy prostate tissue. The optical attenuation coefficient in malignant tissue was significantly higher in malignant tissue compared to benign prostate tissue. Further studies are required to validate these initial results in a larger group of patients with a more tailored histopathology matching protocol.
More Related Videos
08:50Longitudinal Morphological and Physiological Monitoring of Three-dimensional Tumor Spheroids Using Optical Coherence Tomography
Published on: February 9, 2019
06:08A Cognitive Fusion-guided Prostate Biopsy Using Multiparametric Magnetic Resonance Imaging and Transrectal Ultrasound
Published on: March 21, 2025
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...