Related Experiment Video
Updated: Mar 26, 2026

PET and MRI Guided Irradiation of a Glioblastoma Rat Model Using a Micro-irradiator
Published on: December 28, 2017
Glioma Recurrence Versus Radiation Necrosis: Single-Session Multiparametric Approach Using Simultaneous
Amarnath Jena1, Sangeeta Taneja, Aashish Gambhir
1From the *PET Suite, Department of Molecular Imaging and Nuclear Medicine, Indraprastha Apollo Hospitals, Sarita Vihar, New Delhi; †Molecular Imaging and Research Centre, Institute of Nuclear Medicine and Allied Sciences, Delhi; and ‡Institute of Radiation Oncology, and §Institute of Neuro Sciences, Indraprastha Apollo Hospitals, Sarita Vihar, New Delhi, India.
Purpose:
This study aimed to investigate the potential of hybrid gadolinium (Gd)-enhanced F-fluoroethyl-L-tyrosine (F-FET) PET/MRI in distinguishing recurrence from radiation necrosis using simultaneously acquired multiple structural and functional parameters.
Methods:
Twenty-six patients (5 female and 21 male patients; mean ± SD age, 51.58 ± 15.97 years) with single or multiple contrast-enhancing brain lesions (n = 32) on MRI after surgery and radiation therapy were evaluated with simultaneously acquired Gd-enhanced F-FET PET/MRI. They were then followed up with resurgery and histopathological diagnosis (n = 9) and/or clinical/MRI- or PET/MRI-based imaging follow-up (n = 17). PET/MR images were analyzed using manually drawn regions of interest over areas of maximal contrast enhancement and/or FET uptake. Maximum target-to-background ratio (TBRmax), mean target-to-background ratio (TBRmean), and choline-to-creatine (Cho/Cr) ratios as well as normalized mean relative cerebral blood volume (rCBVmean) and mean apparent diffusion coefficient (ADCmean) were determined. The accuracy of each parameter individually and in various possible combinations for differentiating recurrence versus radiation necrosis was evaluated using 2-tailed independent samples Student t test, multivariate analysis of variance, and multivariate receiver operating characteristic analysis. Positive histopathological finding and long-term imaging/clinical follow-up suggestive of disease progression served as criterion standard.
Results:
Of 26 patients, 19 were classified as recurrence, with 7 patients showing radiation necrosis. Individually, TBRmax, TBRmean, ADCmean, and Cho/Cr ratios as well as normalized rCBVmean was significant in differentiating recurrence from radiation necrosis, with an accuracy of 93.8% for TBRmax, 87.5% for TBRmean, 81.3% for ADCmean, 96.9% for Cho/Cr ratio, and 90.6% for normalized rCBVmean. The accuracy of both normalized rCBVmean and ADCmean was improved in combination with TBRmax or Cho/Cr ratio. However, TBRmax (or TBRmean) with Cho/Cr ratio yielded the highest accuracy, approaching up to 97%. Furthermore, maximum area under the curve is achieved with the combination of TBRmean, CBV, and Cho/Cr values.
Conclusions:
Our findings suggest that FET uptake with Cho/Cr ratio and normalized rCBVmean could be most useful to distinguish primary glioma recurrence from radiation necrosis. Hybrid simultaneous multiparametric F-FET PET/MRI might play a significant role in the evaluation of patients with suspected glioma recurrence.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET