X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
Radiography and fluoroscopy, 1920 to the present
Abstract:
A survey of radiological procedures carried out in 1980 by J. L. Johnson and D. L. Abernathy indicated that of the 181 million procedures performed in that year, there were 77.5% plain radiographic studies, 12.7% contrast studies, 4.0% sonographic studies, 3.2% nuclear medicine studies, 1.8% CT studies and 0.8% special vascular procedures and cardiac catheterizations. Note that over 90% of all the studies were of the "conventional" type and that fewer than 2% were CT studies. In the early 70's when CT was introduced, it was predicted that it would soon take over most of radiography; some 7 or 8 years later, it was obvious that this would not take place. According to Tanako of the Fuji Photo Film Co. Ltd., conventional radiography has resisted being pushed aside because of its very high information content: 4-6 megabytes per image. A CT image contains about 0.5 megabytes. If a system is to take over from conventional radiography, it will have to overcome this large difference in information content. Digital or computed radiography seems capable of this, but probably not for some time (perhaps, 10 or 20 years). It seems unlikely that there will be much change, except for refinement, in the image intensified fluoroscopy equipment used for observing dynamic processes, and it will probably not be replaced. Another situation which will preclude the rapid demise of conventional radiography is financial inertia: There is between 5 and 10 billion dollars worth of diagnostic equipment in hospitals in this country and significant amount more in private offices and clinics. It is true that the amount has diminished in recent years, but this has been more because of DRG's than because of "takeover" by new modes of imaging. It is not likely that this investment will be given up quickly or easily. One must also keep in mind that the film digitization and the photostimulable phosphor digital systems, described above, do use existing radiographic equipment, and the image intensification system uses a great portion of existing fluoroscopic equipment, therefore "going digital" may not require complete replacement of existing equipment.
More Related Videos
Related Concept Videos
X-ray Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation I: X-ray and CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...