Related Experiment Video
Updated: Mar 26, 2026

A 3D-printed Chamber for Organic Optoelectronic Device Degradation Testing
Published on: August 10, 2018
The Effect of Different Water Temperatures on Retention Loss and Material Degradation of Locator Attachments
Lillian Pui Yuk Chiu1, Nicola Di Vitale1, Haralampos Petridis1
1Prosthodontics Unit, Department of Restorative Dentistry, UCL, Eastman Dental Institute, London, UK.
Purpose:
To examine the changes in Locator attachments after exposure to different water temperatures and cyclic loading.
Materials And Methods:
Four groups of pink Locator attachments (3.0 lb. light retention replacement patrix attachments; 10 per group) were soaked for the equivalent of 5 years of use in distilled water at the following temperatures: 20°C, 37°C, 60°C. One group was kept dry to test the effect of water. A universal testing machine was used to measure the retention force of each treated attachment during 5500 insertion and removal cycles, simulating approximately 5 years of use. The results were compared using Kruskal-Wallis one-way ANOVA by ranks. Surface changes of tested attachments were examined using scanning electron microscopy (SEM).
Results:
The exposure to 60°C water significantly increased the percentage of retention loss in Locator attachments (p < 0.05) compared to the 20°C water group and significantly reduced the final retention force compared to the other groups (p < 0.05). SEM examinations revealed severe cracking and material degradation in Locator attachments after exposure to 60°C water and cyclic loading, which were not evident in other groups. Cracking was observed after exposure to 60˚C water before cyclic loading.
Conclusions:
Exposure to 60°C water, potentially similar to denture cleansing procedures, could cause cracking in Locator attachments. Cracking is associated with hydrolytic degradation of nylon at 60°C. The change in structure could result in a significant loss of retention.
More Related Videos
Related Concept Videos
Design Example: Managing Concrete Workability
Hot Weather Concreting
Mitigating the heat increase in concrete can be economically achieved by shading aggregate stockpiles to prevent heating from solar radiation,...
Cold Weather Concreting
To counteract the negative impacts of cold weather, ensuring...
Testing Water Quality
Porosity and Absorption of Aggregate
When all pores in an aggregate are filled with water, the aggregate is considered saturated and surface-dry. If left in dry air, water will evaporate until the...
Strength and Heat of Hydration
The heat of hydration for each cement compound is significant; for instance, tricalcium aluminate (C3A) and...