Evaluation of the Effects of Hidden Node Problems in IEEE 802.15.7 Uplink Performance

Carlos Ley-Bosch1,2, Itziar Alonso-González3,4, David Sánchez-Rodríguez5,6

  • 1Institute for Technological Development and Innovation in Communications, Edificio Polivalente II, 2aplanta, Parque Científico y Tecnológico, Campus Universitario de Tafira, Las Palmas de Gran Canaria 35017, Spain. carlos.ley@ulpgc.es.

Related Concept Videos

Transmission Line Design Considerations01:23

Transmission Line Design Considerations

Aluminum has become the material of choice for overhead transmission lines, surpassing copper due to its abundance and cost-effectiveness. The most prevalent type is the aluminum conductor, steel-reinforced (ACSR), which combines aluminum strands around a steel core. Other variants include all-aluminum conductors (AAC), all-aluminum alloy conductors (AAAC), aluminum conductor alloy-reinforced (ACAR), and aluminum-clad steel conductors. Advanced designs, such as aluminum conductors with steel...
709
Maximum Power Transfer01:16

Maximum Power Transfer

Numerous practical applications within engineering disciplines, such as telecommunications, necessitate optimizing power delivery to a connected load. This pursuit, however, entails inherent internal losses, which can either equal or exceed the power supplied to the load. The Thevenin equivalent circuit is helpful in finding the maximum power a linear circuit can deliver to a load. It is assumed in this context that the load resistance can be adjusted.
By substituting the entire circuit with...
1.1K
Cable Subjected to a Distributed Load01:24

Cable Subjected to a Distributed Load

The analysis of suspension bridges is a complex and critical process that involves multiple factors, including the shape and tension of the main cables. The main cables of suspension bridges are subjected to distributed loads, which result in changes in tensile forces and deformation of the cable. These loads must be carefully considered to ensure that the bridge is safe and capable of supporting the weight of different loads.
1.3K
Maximum Power Flow and Line Loadability01:23

Maximum Power Flow and Line Loadability

The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
702
Lossy Lines and Overvoltages01:22

Lossy Lines and Overvoltages

Transmission-line series resistance and shunt conductance cause three primary effects: attenuation, distortion, and power losses.
Attenuation
When constant series resistance and shunt conductance are present, voltage and current equations are modified. The propagation constant indicates that voltage and current waves consist of both forward and backward traveling components. These waves attenuate as they propagate, with the attenuation factor related to the resistance and conductance. In a...
385
Distributed Loads: Problem Solving01:21

Distributed Loads: Problem Solving

Beams are structural elements commonly employed in engineering applications requiring different load-carrying capacities. The first step in analyzing a beam under a distributed load is to simplify the problem by dividing the load into smaller regions, which allows one to consider each region separately and calculate the magnitude of the equivalent resultant load acting on each portion of the beam. The magnitude of the equivalent resultant load for each region can be determined by calculating...
1.2K