Insights
Lower oxygen saturation targets (85–89%) in preterm infants did not significantly increase death or disability in individual trials. However, combined analyses showed higher risks of death or disability and death alone in the lower-target group.
Area of Science:
- Neonatalogy
- Pediatric Critical Care
- Clinical Trials
Background:
- Optimal oxygen saturation ranges for preterm infants remain debated.
- Ensuring adequate oxygenation while preventing hyperoxia-related complications is critical for extremely preterm neonates.
Purpose of the Study:
- To investigate the effects of lower versus higher oxygen saturation targets on death or disability in preterm infants.
- To determine the safest oxygen saturation range for infants born before 28 weeks' gestation.
Main Methods:
- Two randomized controlled trials were conducted in Australia and the United Kingdom.
- Infants were assigned to lower (85–89%) or higher (91–95%) oxygen saturation ranges.
- The primary outcome was death or disability at 2 years corrected gestational age.
Main Results:
- Interim analysis led to trial stoppage due to increased mortality.
- Post hoc combined analyses revealed significantly higher risks of death or disability (RR 1.11) and death alone (RR 1.20) in the lower-target group.
- In analyses using revised oximeters, the lower-target group showed significantly higher mortality (RR 1.45).
Conclusions:
- Targeting lower oxygen saturation (85–89%) in preterm infants was associated with increased risks of death or disability and death alone in combined analyses.
- These findings suggest that higher oxygen saturation targets may be safer for extremely preterm infants.
- Further research is needed to refine oxygen management strategies in neonatal intensive care.
Background:
The safest ranges of oxygen saturation in preterm infants have been the subject of debate.
Methods:
In two trials, conducted in Australia and the United Kingdom, infants born before 28 weeks' gestation were randomly assigned to either a lower (85 to 89%) or a higher (91 to 95%) oxygen-saturation range. During enrollment, the oximeters were revised to correct a calibration-algorithm artifact. The primary outcome was death or disability at a corrected gestational age of 2 years; this outcome was evaluated among infants whose oxygen saturation was measured with any study oximeter in the Australian trial and those whose oxygen saturation was measured with a revised oximeter in the U.K. trial.
Results:
After 1135 infants in Australia and 973 infants in the United Kingdom had been enrolled in the trial, an interim analysis showed increased mortality at a corrected gestational age of 36 weeks, and enrollment was stopped. Death or disability in the Australian trial (with all oximeters included) occurred in 247 of 549 infants (45.0%) in the lower-target group versus 217 of 545 infants (39.8%) in the higher-target group (adjusted relative risk, 1.12; 95% confidence interval [CI], 0.98 to 1.27; P=0.10); death or disability in the U.K. trial (with only revised oximeters included) occurred in 185 of 366 infants (50.5%) in the lower-target group versus 164 of 357 infants (45.9%) in the higher-target group (adjusted relative risk, 1.10; 95% CI, 0.97 to 1.24; P=0.15). In post hoc combined, unadjusted analyses that included all oximeters, death or disability occurred in 492 of 1022 infants (48.1%) in the lower-target group versus 437 of 1013 infants (43.1%) in the higher-target group (relative risk, 1.11; 95% CI, 1.01 to 1.23; P=0.02), and death occurred in 222 of 1045 infants (21.2%) in the lower-target group versus 185 of 1045 infants (17.7%) in the higher-target group (relative risk, 1.20; 95% CI, 1.01 to 1.43; P=0.04). In the group in which revised oximeters were used, death or disability occurred in 287 of 580 infants (49.5%) in the lower-target group versus 248 of 563 infants (44.0%) in the higher-target group (relative risk, 1.12; 95% CI, 0.99 to 1.27; P=0.07), and death occurred in 144 of 587 infants (24.5%) versus 99 of 586 infants (16.9%) (relative risk, 1.45; 95% CI, 1.16 to 1.82; P=0.001).
Conclusions:
Use of an oxygen-saturation target range of 85 to 89% versus 91 to 95% resulted in nonsignificantly higher rates of death or disability at 2 years in each trial but in significantly increased risks of this combined outcome and of death alone in post hoc combined analyses. (Funded by the Australian National Health and Medical Research Council and others; BOOST-II Current Controlled Trials number, ISRCTN00842661, and Australian New Zealand Clinical Trials Registry number, ACTRN12605000055606.).
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Transport in the Blood