Related Experiment Video
Updated: Mar 25, 2026

Capillary Electrophoresis to Monitor Peptide Grafting onto Chitosan Films in Real Time
Published on: October 26, 2016
Development and validation of a cyclodextrin-modified capillary electrophoresis method for the enantiomeric
Adrienn Kazsoki1, Ida Fejős1, Tamás Sohajda2
1Department of Pharmacognosy, Semmelweis University, Budapest, Hungary.
Abstract:
The enantiomers of vildagliptin, an orally available and selective dipeptidyl-peptidase-4 inhibitor used for the treatment of type II diabetes, have been separated by CD-modified CZE, using uncoated fused-silica capillary. After screening 13 negatively charged CD derivatives as potential chiral selectors, sulfobutyl-ether-α-CD (SBE-α-CD) was selected for the enantioseparation. For the optimization, a factorial analysis study was performed by orthogonal experimental design. Six experimental factors were chosen as variable parameters: temperature, applied voltage, chiral selector and BGE concentrations, pH, and the parameters of the hydrodynamic injection. The optimized system still was not considered final as the second peak (S-enantiomer) migrated too close to the EOF, resulting in a potential inaccuracy during the determination of the chiral impurity. To fine-tune the method "one factor at a time" variation approach was applied. The final method (applying 15°C capillary temperature, 40 mbar × 4 s hydrodynamic injection, 25 kV voltage in 75 mM acetate-Tris buffer [pH 4.75] containing 20 mM SBE-α-CD as chiral selector) was validated according to the ICH guideline. RSD percentage of the resolution value, migration times, and corrected peak areas were below 5% during testing repeatability and intermediate precision. LOD and LOQ values were found to be 2.5 and 7.5 μg/mL, respectively. The method is considered linear in the 7.5-180 μg/mL range for the R-enantiomer. The robustness of the method was justified using Plackett-Burmann statistical experimental design.
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Capillary Electrophoresis: Instrumentation
Electrophoresis: Overview
There...
Ion-Exchange Chromatography