Related Experiment Video
Updated: Mar 25, 2026

Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
[Virtual unenhanced images derived from spectral CT imaging accessing gastric carcinoma: a feasible study]
Yaru Chai1, Jianbo Gao, Jingjing Xing
1Department of Radiology, First Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, China.
Objective:
To qualitatively and quantitatively compare MSI images and WB images derived from spectral CT imaging with CU images in accessing gastric carcinoma.
Methods:
The clinical data and imaging findings of 91 cases of gastric carcinomas between December 2013 and May 2015 were analyzed retrospectively. All patients underwent CU CT and enhanced CT with spectral imaging in AP and VP. MSI images were reconstructed based on monochromatic images of 70 keV in AP. WB images were obtained by water-iodine pair substance isolation of the AP images. Two abdominal radiologists independently evaluated the image quality and the depiction of gastric carcinoma in CU, MSI and WB images using a 5-point scale. The sensitivities of gastric cancer were evaluated by using enhanced images as the reference standard.The CT number of various regions, image noise, relative enhancement CT value of tumors and metastasis were measured and calculated on CU and MSI images. The CNR of gastric tumor were measured on CU, MSI and WB images. Effective radiation doses for triple-phase and dual-phase scan were calculated. Differences were tested for statistical significance using the Wilcoxon's signed rank test and the paired t-test.
Results:
Interobserver agreement with regard to image quality and the depiction of gastric carcinoma was good(all kappa>0.70). There was no statistical significant difference in image quality between CU(4.30±0.63) and MSI(4.17±0.58) images(P>0.05), both higher than WB(3.87±0.84) images (both P<0.01). The depiction of gastric carcinoma in CU(3.86±0.50) and MSI(3.73±0.55) images had no statistical significant difference (P>0.05), and both higher than WB(3.34±0.38) images( both P<0.01). The sensitivities of CU, MSI and WB images were 91.2%, 95.6%, 93.4%. The CT number of gastric tumors, liver metastasis and aorta, image noise on MSI images were slightly higher than on TNE images(P<0.05). The CT number of gastric tumors, liver metastasis and aorta, image noise on MSI images were slightly higher than on TNE images(P<0.05). The CT number of lymph nodes, liver and muscle, CT relative enhancement value of gastric tumors, lymph nodes and liver metastasis had no significant difference between TNE and MSI images (all P>0.05). The CNR of gastric tumors had significant difference between groups: WB images were higher than MSI and MSI were higher than CU images(all P<0.01). The dose saving by removing the CU was 8.2 mSv(32%).
Conclusion:
The MSI images derived from spectral CT can provide comparable image quality to CU images and reliable diagnostic information for gastric tumors, which is superior to WB images, replacing CU images will lower radiation exposure by 32%.
More Related Videos
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
08:41Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease
Published on: March 24, 2023
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...