LV mechanical dispersion as a predictor of ventricular arrhythmia in patients with advanced systolic heart failure :
G Banasik1, O Segiet2, M Elwart2
1Medical University of Silesia in Katowice, School of Medicine with the Division of Dentistry in Zabrze, Zabrze, Poland. macgrzegorz@gmail.com.
Background:
Myocardial mechanical dyssynchrony induced by the presence of postinfarction scar and/or conduction abnormalities in patients with a left ventricular ejection fraction (LVEF) of < 35 % may be associated with a greater propensity toward inducing serious ventricular arrhythmia [(ventricular tachycardia (VT), ventricular fibrillation (VF)] and sudden cardiac death. The assessment of regional myocardial function using tissue Doppler echocardiography (TDE) allows for noninvasive analysis of regional mechanical dysfunction (LV mechanical dispersion).
Aim:
The aim of this study was to evaluate the TDE-based mechanical dispersion as a potential echocardiographic predictor of VT/VF.
Methods:
The study group consisted of 47 consecutive ambulatory patients with implanted cardiac resynchronization therapy-defibrillator (CRT-D) devices who were divided into two groups: Group 1 (n = 29) comprised patients with recorded episodes of VT/VF, in whom baseline TDE data were available, and group 2 (n = 18) comprised patients without registered VT/VF in the device memory within 4 years after implantation. LV mechanical dispersion was defined as the standard deviation of the time measured from the beginning of the QRS complex to the peak longitudinal strain in apical four-chamber and two-chamber views. A retrospective quantitative assessment of LV regional deformation was based on the color tissue velocity recordings.
Results:
The average time to event after implantation was 345 days. Patients with electrical events demonstrated greater mechanical dispersion: 99.14 ± 33.60 vs. 72.98 ± 19.70, p=0.002.
Conclusion:
During the 4-year follow-up, patients with documented VT/VF were characterized by significantly higher LV mechanical dispersion as compared with patients without electrical events. Measurement of LV mechanical dispersion might be helpful in determining the risk of sudden cardiac death.
More Related Videos
06:10Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
Related Concept Videos
Cardiomyopathy II: Dilated Cardiomyopathy
Heart Failure II: Pathophysiology
Mechanism of Cardiac Arrhythmias
Heart Failure Drugs: β-Blockers
Pathophysiology of Heart Failure
Heart Failure VI: Adjunct Therapies