Related Experiment Video
Updated: Mar 25, 2026

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
A Prospective Study on Functional Outcome of Internal Fixation of Tibial Pilon Fractures with Locking Plate using
Arjun Ballal1, H Ravindranath Rai2, Siddharth M Shetty3
1Consultant Orthopaedic Surgeon, Department of Orthopaedic Surgery, Udupi , Karnataka, India .
Introduction:
Managing pilon fractures is still a great challenge for surgeons in terms of reduction and fixation. The soft tissue anatomy and the bony configuration, results in angular and rotational instability and other bony and soft tissue complications.
Aim:
To evaluate the results of minimally invasive plate osteosynthesis using locking plates in management of fractures of tibial pilon in terms of radiological fracture union, restoration of ankle function and complications.
Materials And Methods:
A total of 18 patients with Ruedi Allgower class I, II & III fresh pilon fractures were taken into this study. All the patients underwent ankle spanning external fixator application on the day of presentation as a first stage. Wound debridement was done in patients with open fractures. Associated distal fibula fractures were fixed in the first stage. The second stage comprised of a definitive plate fixation using the minimally invasive plate osteosynthesis technique. This employed minimal periosteal and soft tissue dissection through a medial approach to the ankle. Postoperatively, all patients were reviewed at week six and 12 when partial weight bearing and full weight bearing mobilization was started respectively. The final review was done at 24 weeks when the final assessment of function was done as per the Mazur's scoring criteria. Analyses were done using frequency and proportions. Chi-square tests were used to assess the test of association.
Results:
Three patients had excellent inference, nine patients had good inference, five patients had fair and one patient had poor inference as per the Mazur's scoring criteria. Two patients had scar dehiscence as a complication and one patient had a fixed equines deformity of the ankle who was under RuediAllgower class III.
Conclusion:
Minimally invasive plate osteosynthesis is an excellent method of treating pilon fractures with very good functional results and minimal complication rate.
More Related Videos
07:41An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
Published on: November 13, 2016
05:34A Mini-Invasive Internal Fixation Technique for Studying Immobilization-Induced Knee Flexion Contracture in Rats
Published on: May 20, 2019