Patient dose measurement in common medical X-ray examinations in Iran
Behrouz Rasuli1, Ali Mahmoud-Pashazadeh, Mohammad Ghorbani
1Behbahan Faculty of Medical Sciences. rasuli-b@ajums.ac.ir.
Abstract:
The main purpose of this study was to investigate patient dose in the chest (PA/AP/LAT) and skull (PA/AP/LAT) X-ray examinations, as frequent procedures. The study was performed in eight public hospitals of Khuzestan province, Iran. Patient dosimetry was conducted on 567 standard patient X-ray examinations (males: 61.2%, female: 38.2%). Dosimetry protocol in this study was indirect method, according to the International Atomic Energy Agency (IAEA) Technical Reports series No.457. Patients weighing 70 ± 10 kg were considered as standard. In the indirect dosimetry approach, exposure parameters such as kVp, mAs, focal film distance (FFD), and tube outputs recorded during data acquisition were used for calculating incident air kerma on the patient's skin, entrance surface air kerma (ESAK) that is recommended by the IAEA as the most appropriate patient dosimetry quantity in simple radiographic examinations. This survey reveals significant variations in the radiological practice. Results showed that the parameters set by radiologic technologists change in a wide range: mAs varied from 2 to 80 for skull PA, 2 to 202 for chest LAT, and FFD varied from 50 to 180 for skull LAT projection. The study showed that patient doses in three chest projections exceed the IAEA and European Commission dose reference levels (EC DRLs) - 1.0, 1.12, and 2.20 mGy for chest PA, chest AP, and chest LAT, respectively. Results also showed that mean ESAKs of patients in skull projections were generally lower than the IAEA and EC DRLs, 1.5, 1.72, and 2.25 for skull LAT, skull AP, and skull PA, respectively. This study provides evidence that dose reduction in the simple X-ray examinations is feasible by updating clinical audits and implementation of systematic quality assurance (QA) and quality control (QC) programs. The authors recommend that DRLs obtained in this study can be used as local DRLs in Khuzestan area and dose surveys must be performed in all provinces to establish national dose reference levels (NDRLs) in Iran.
Related Concept Videos
Radiological Investigation I: X-ray and CT
X-ray Imaging
Biological Effects of Radiation
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...