Dynamic filling parameters in patients with atrial fibrillation: differentiating rhythm induced from
Piet A H Wyffels1, Frederic Van Heuverswyn2, Stefan De Hert3
1Department of Anesthesiology, Ghent University Hospital, Ghent, Belgium; and Piet.wyffels@ugent.be.
Abstract:
In patients with sinus rhythm, the magnitude of mechanical ventilation (MV)-induced changes in pulse pressure (PP) is known to predict the effect of fluid loading on cardiac output. This approach, however, is not applicable in patients with atrial fibrillation (AF). We propose a method to isolate this effect of MV from the rhythm-induced chaotic changes in PP in patients with AF. In 10 patients undergoing pulmonary vein ablation for treatment of AF under general anesthesia, ECG and PP waveforms were analyzed during apnea (T1) and during MV at tidal volumes of 8 ml/kg (T2) and 12 ml/kg (T3), respectively. In a first step, three mathematical models were compared in their ability to predict individual PP at T1. The best-fitting model was then selected as the reference to quantify the effects of MV on PP in these patients. A local polynomial regression model based on two preceding RR intervals (LOC2) was found to be superior over the quadratic models to predict PP. LOC2 was therefore selected to quantify variations in PP induced by MV. During T2 and T3, magnitude of PP deviations was related with the amplitude of tidal volume [mean bias error (SD) of -5 (6) and -8 (7) mmHg for T2 and T3, respectively; P = 0.003 repeated-measures ANOVA]. We conclude that LOC2 most accurately predicted rhythm-induced variations in PP. MV-induced deviations in PP can be quantified and may therefore provide a method to study cardiopulmonary interactions in the presence of arrhythmia.
More Related Videos
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
04:48Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
Related Concept Videos
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Respiratory Volumes and Capacities I
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Dysrhythmias III: Characteristics of Dysrhythmias
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...