Related Experiment Video
Updated: Mar 25, 2026

Fabrication and Testing of Photonic Thermometers
Published on: October 24, 2018
A SQUID-based primary noise thermometer for low-temperature metrology
1Physikalisch-Technische Bundesanstalt (PTB), Abbestrasse 2-12, 10587 Berlin, Germany.
A new DC superconducting quantum interference device-based noise thermometer enables precise thermodynamic temperature measurements from 5 K down to 1 mK. This primary magnetic field fluctuation thermometer achieves a relative combined standard uncertainty of 0.6%.
Area of Science:
- Physics
- Metrology
- Thermodynamics
Background:
- Accurate temperature measurements are crucial for scientific advancement and require traceability to international standards.
- The upcoming redefinition of the kelvin based on the Boltzmann constant necessitates advanced primary thermometry methods.
- Existing methods face limitations in the broad temperature ranges required for fundamental research.
Purpose of the Study:
- To develop and validate a novel DC superconducting quantum interference device-based noise thermometer.
- To enable primary thermometry for the realization and dissemination of the kelvin.
- To measure thermodynamic temperature accurately across a wide range, from 5 K down to below 1 mK.
Main Methods:
- Development of a DC superconducting quantum interference device (SQUID) based noise thermometer.
- Detailed description of the primary magnetic field fluctuation thermometer and its underlying thermodynamic temperature determination model.
- Experimental validation through comparison with the Provisional Low Temperature Scale 2000 (PLTS-2000).
Main Results:
- The developed thermometer successfully measures thermodynamic temperature in the range of 0.7 K to 16 mK.
- Experimental results show excellent agreement with the PLTS-2000.
- A relative combined standard uncertainty of 0.6% was achieved for the thermodynamic temperature measurements.
Conclusions:
- The DC SQUID-based noise thermometer is a viable primary thermometry technique for realizing and disseminating the kelvin.
- This instrument provides accurate thermodynamic temperature measurements in the millikelvin range with low uncertainty.
- The findings support the transition to a new SI definition of temperature based on fundamental constants.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Thermometers and Temperature Scales
As many physical properties depend on temperature, the variety of thermometers is...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Gas Thermometers and the Kelvin Scale
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...