Dependence of Laser-induced Breakdown Spectroscopy Results on Pulse Energies and Timing Parameters Using Soil Simulants
Published on: September 23, 2013
11.8K
Background removal in soil analysis using laser- induced breakdown spectroscopy combined with standard addition
Optics Express
|February 25, 2016
Summary
Reducing matrix effects in laser-induced breakdown spectroscopy (LIBS) for soil analysis is crucial. A novel standard addition method (SAM) combined with wavelet transform background removal significantly improved lead (Pb) and cadmium (Cd) concentration prediction accuracy.
Area of Science:
- Analytical Chemistry
- Spectroscopy
- Environmental Science
Background:
- Matrix effects in laser-induced breakdown spectroscopy (LIBS) significantly impact elemental concentration prediction accuracy, particularly for soil samples.
- Accurate elemental analysis of soil is vital for environmental monitoring and remediation.
Purpose of the Study:
- To investigate a novel standard addition method (SAM) combined with wavelet transform for background removal to mitigate matrix effects in LIBS analysis of soil samples.
- To enhance the prediction accuracy of elemental concentrations, specifically lead (Pb) and cadmium (Cd), in soil.
Main Methods:
- Utilized five certified reference soil samples with varying lead (Pb) concentrations (110–1141 ppm).
- Applied a standard addition method (SAM) incorporating background removal via wavelet transform algorithm.
- Compared results with the conventional calibration method.
Main Results:
- The conventional calibration method yielded a root mean square error of prediction (RMSEP) over 303 ppm for Pb.
- The proposed SAM with wavelet transform background removal reduced the RMSEP to 25.7 ppm for Pb.
- The method demonstrated potential for improving the predicted accuracy of other elements, such as Cadmium (Cd).
Conclusions:
- The standard addition method combined with wavelet transform background removal effectively reduces matrix effects in LIBS analysis of soil.
- This approach significantly enhances the accuracy of elemental concentration prediction in soil samples.
- The developed method offers a robust solution for more reliable elemental analysis in environmental applications.
More Related Videos
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
1.3K
For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
1.3K
Atomic Absorption Spectroscopy: Interference
2.3K
Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
2.3K
Atomic Absorption Spectroscopy: Overview
4.2K
Atomic absorption spectroscopy (AAS) is a technique used to analyze elements by measuring electromagnetic radiation (EMR) absorbed by atoms, which causes them to transition to a higher-energy orbit. The most crucial step in AAS is atomization, where the analyte is converted into gas-phase atoms, typically through a flame or furnace. Some of these atoms become thermally excited in the flame, while most remain in the ground state.
When irradiated by EMR of a particular wavelength, these...
When irradiated by EMR of a particular wavelength, these...
4.2K