Related Experiment Video
Updated: Mar 25, 2026

Technique and Patient Selection Criteria of Right Anterior Mini-Thoracotomy for Minimal Access Aortic Valve Replacement
Published on: March 26, 2018
Respiratory System Function in Patients after Aortic Valve Replacement through Right Anterior Minithoracotomy
Jarosław Stoliński1, Dariusz Plicner1, Kamil Fijorek2
1Department of Cardiovascular Surgery and Transplantology, John Paul II Hospital Jagiellonian University, Krakow, Poland.
Abstract:
Background The aim of the study was to analyze respiratory system function after minimally invasive aortic valve replacement through right anterior minithoracotomy (RAT-AVR). Methods An observational study of 187 patients electively scheduled for RAT-AVR between January 2010 and December 2013. Pulmonary complications were analyzed and spirometry examinations were performed preoperatively, 1 week, 1 month, and 3 months after surgery. Results Hospital mortality was 1.1%. A double-lumen intratracheal tube was used in 88.2% and single-lumen intratracheal tube was used in 11.8% of patients. Pulmonary complications occurred in 10.8% of the patients. Prolonged (>24 hours) mechanical ventilation time was present in five patients (2.7%). The reasons were stroke (n = 1), perioperative myocardial infarction (n = 2), and pneumothorax (n = 2). Right pleural effusion, which occurred in 7.7% (n = 14) of patients, was the most frequent respiratory system complication. One week after surgery, the spirometry parameters decreased in comparison to the preoperative period, then after 3 months statistically significant improvement occurred; however, the spirometry parameters still had not returned to preoperative values. Multivariable median regression analysis shows that the presence of chronic obstructive pulmonary disease and pulmonary complications were associated with lower values of forced expiratory volume in 1 second after surgery. There was no statistically significant difference regarding spirometry values or incidence of pulmonary complications after surgery between patients in whom single-lung or double-lung ventilation was applied. Conclusion Pulmonary functional status measured with spirometry parameters was diminished after RAT-AVR surgery. Single-lung ventilation did not result in a higher rate of respiratory complications after RAT-AVR surgery.
Related Concept Videos
Cardiopulmonary Resuscitation II: ACLS Airway Management
Aortic Regurgitation III: Medical Management
Aortic Regurgitation IV: Nursing Management
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Aortic Regurgitation I: Introduction
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...

